724   Fewer Ethernet ports active.

Explanation

An Ethernet port that was previously operational is no longer operational. The physical link is down.

Data:

Three numeric values are listed:
  • The ID of the first unexpected inactive port. This is a decimal number.
  • The ports that are expected to be active. This is a hexadecimal number. Each bit position represents a port, with the least significant bit representing port 1. The bit is 1 if the port is expected to be active.
  • The ports that are actually active. This is a hexadecimal number. Each bit position represents a port, with the least significant bit representing port 1. The bit is 1 if the port is active.

User response

  1. If possible, use the management GUI to run the recommended actions for the associated service error code.
  2. Contact your hardware manufacturer.