lsenclosurebattery
Use the lsenclosurebattery command to display information about the batteries. The batteries are located in the node canisters.
Syntax
>>- -- lsenclosurebattery -- --+----------+-- ------------------> '- -nohdr -' >--+-----------------------------------+-- ---------------------> '- -filtervalue -- attribute_value -' >--+-----------------+-- --+-----------------------+-- ---------> '- -filtervalue? -' '- -delim -- delimiter -' >--+----------------------------------------------+-- --------->< '-+--------------------------+-- enclosure_id -' '- -battery -- battery_id -'
Parameters
- -nohdr
- (Optional) By default, headings are displayed for each column of data in a concise style view,
and for each item of data in a detailed style view. The -nohdr parameter
suppresses the display of these headings.Note: If there is no data to be displayed, headings are not displayed.
- -filtervalue attribute=value
- (Optional) Specifies a list of one or more filters. Only objects with a value that matches the filter attribute value are returned. If a capacity is specified, the units must also be included.
- Note: Some filters allow the use of a wildcard when you enter the command. The following rules apply to the use of wildcards when you use the CLI:
- The wildcard character is an asterisk (*).
- The command can contain a maximum of one wildcard.
- When you use a wildcard, you must enclose the filter entry within double quotation marks
(""), as follows:
lsenclosurebattery -filtervalue "battery_id=1"
- -filtervalue?
- (Optional) Displays a list of valid filter attributes for the -filtervalue attribute=value parameter:
- battery_id
- charging_status
- enclosure_id
- end_of_life_warning
- percent_charged
- recondition_needed
- status
- -delim delimiter
- (Optional) By default in a concise view, all columns of data are space-separated. The width of each column is set to the maximum width of each item of data. A detailed view provides each item of data in its own row, and if the headers are displayed, the data is separated from the header by a space. The -delim parameter overrides this behavior. Valid input for the -delim parameter is a 1-byte character. If you enter -delim : on the command line, the colon character (:) separates all items of data in a concise view; for example, the spacing of columns does not occur. In a detailed view, the data is separated from its header by the specified delimiter.
- -battery battery_id
- (Optional) Provides a detailed view of the specified battery. Valid only when an enclosure is specified.
- enclosure_id
- (Optional) Lists the batteries for the specified enclosure.
Description
This command displays information about the batteries, which are located in the node canisters. The concise view displays a line for each battery slot in every enclosure whether a battery exists for that slot or not. Batteries are not shown for expansion enclosures.Table 1
shows possible outputs.
| Attribute | Description |
|---|---|
| enclosure_id | Identifies the identity of the enclosure that contains the battery. |
| battery_id | Identifies the battery in the enclosure. |
| status | Identifies the status of the battery:
|
| recondition_needed | Identifies that the battery needs to be reconditioned or it must start reconditioning
soon. Remember: If this message is permanent, there might be an
error that prevents the recondition from starting.
|
| percent_charged | Indicates the charge of battery (in a percentage). |
| end_of_life_warning | Identifies the battery's end of life (with a warning noise). The values are
yes and no. Important: Replace the
battery.
|
| FRU_part_number | Identifies the FRU part number of the battery. |
| FRU_identity | Identifies the 11S number, combining the manufacturing part number and the serial number. |
| firmware_level | The version of the microcode image that is installed on the battery. |
| error_sequence_number | Indicates the error log (or event log) number of the highest priority error for this object. This output field is typically blank. However, if there is a problem (for example, the status is degraded), then it contains the sequence number of that error event. |
| remaining_charge_capacity_mAh | Identifies the battery's remaining charge capacity in milliampere-hour (mAh). |
| full_charge_capacity_mAh | Identifies the fully charged capacity of the battery in mAh (this value diminishes as the battery ages). |
| compatibility_level | Identifies the battery driver software must support this level to operate with this battery - this value comes from the battery vital product data (VPD). |
| last_recondition_timestamp | Identifies a system timestamp, in the format YYMMDDHHMMSS,
for when the last successful calibration of the gas gauge occurred, where:
|
| powered_on_hours | Identifies the number of hours the battery is in a powered node (not necessarily the same node). |
| cycle_count | Identifies the number of charge or discharge cycles that are performed on the battery. |
A concise invocation example
lsenclosurebattery 1
The resulting output:
enclosure_id battery_id status charging_status recondition_needed percent_charged end_of_life_warning
1 1 online idle no 100 no
1 2 online idle no 100 no
A detailed invocation example
lsenclosurebattery -battery 1 1
The resulting output:
enclosure_id 1
battery_id 1
status online
charging_status idle
recondition_needed no
percent_charged 100
end_of_life_warning no
FRU_part_number 31P1807
FRU_identity 11S00AR085YM30BG42R04P
firmware_level 105:1
error_sequence_number
remaining_charge_capacity_mAh 3477
full_charge_capacity_mAh 3795
compatibility_level 1
last_recondition_timestamp 140528045617
powered_on_hours 1162
cycle_count 10