addcontrolenclosure
Use the addcontrolenclosure command to add control enclosures to the system.
Syntax
Parameters
- -iogrp io_grp_id_or_name
- The I/O group in which you want to put the control enclosure.
- -sernum enclosure_serial_number
- The serial number of the control enclosure you want to add.
- -site site_name | site_id
- (Optional) Specifies the numeric site value or site name of the new control enclosure. The
site can be set to a value of
1or2only.Note: The site that is assigned to a control enclosure cannot be changed if the topology ishyperswap.
Description
Use this command to add a control enclosure to the system.If encryption is enabled, you must enter a license for a new encryption capable node before you add it to the system or the addition fails.
Compressed or thin-deduplicated volumes can be added only to systems in which all nodes support deduplicated volumes. You can add only nodes that support deduplicated volumes to a system that contains compressed or thin deduplicated volumes. Nodes can be added only to a system that contains compressed or thin deduplicated volumes if that new node can support the amount of memory that is allocated for data deduplication in the target I/O group.
An invocation example
addcontrolenclosure -iogrp 0 -sernum 2361443
The following output is displayed:
Enclosure containing Node, id [x], successfully addedAn invocation example
addcontrolenclosure -iogrp 1 -sernum 1234567 -site site2
The following output is displayed:
Enclosure, Node id [2], successfully added