Installing or replacing an expansion canister
You can reinstall an expansion canister in a 5U expansion enclosure or replace a faulty expansion canister with one from FRU stock.
Before you begin
Important: You can replace an expansion canister without powering off the expansion
enclosure. However, to maintain operating temperature, replace the expansion canister within 10
minutes of its removal. When an expansion canister is removed, the reduction in airflow through the
enclosure might cause the enclosure or its components to shut down to protect from
overheating.
About this task
An expansion canister provides SAS connectivity between the 5U expansion enclosure and the system. The expansion enclosure contains two expansion canisters. Figure 1 shows an example of an expansion canister. If either of the two expansion canisters has a failure, the other expansion canister assumes the full I/O load.