Connecting optional 5U expansion enclosures
After you install 5U expansion enclosures into the rack, you must connect them to each system that will use them. The system requires software version 7.8.0 or later. Do not connect the expansion enclosure if software version 7.8.0 is not installed on the system.
About this task
This task applies if you are installing a 5U expansion enclosure.
Note: When you insert SAS cables, ensure that the connector is oriented correctly to the control
enclosure and expansion enclosure.
Be aware of the following guidelines when you attach the cables to the SAS ports.
Procedure
If more I/O groups are configured, repeat the cabling procedure for the other I/O groups. Each
system can have a maximum of four I/O groups, with two chains of expansion enclosures attached to
each I/O group. Two chains of expansion enclosures can be attached to each I/O group. On each SAS
chain, the systems can support up to a SAS chain weight of 10.
Combining 2U and 5U expansion enclosures
About this task
Example
Table 1 shows example of different combinations of SAS weights.
| 2U Enclosures (12 drives) | 2U Enclosures (24 drives) | 5U Enclosures (92 drives) | Combined chain weight |
|---|---|---|---|
| 2 | 0 | 3 | 9.5 |
| 2 | 3 | 2 | 10 |
| 0 | 7 | 1 | 9.5 |
| 1 | 1 | 1 | 4.5 |
In addition, the orientation of the Input and Output SAS ports on the 2U and 5U SAS enclosures differs.