Setting the Fibre Channel port mapping: 2145-SV1
When you upgrade to a SAN Volume Controller 2145-SV1 node, you can preserve the port layout and worldwide port names (WWPNs) from the existing node. To do so, you can change which physical ports are mapped to particular Fibre Channel I/O ports on the 2145-SV1 node.
Determining adapter slot locations
In most cases, you can use one of the standard port mappings when you are replacing a SAN Volume Controller 2145-DH8 , SAN Volume Controller 2145-CF8, or 2145-CG8 node.
Table 1 describes the standard port mapping on a 2145-SV1 node. To use the table, locate the row that fully describes the location and type of Fibre Channel (FC) and Ethernet adapters in your existing node. If you set the pre-defined port mapping in the -fcportmap column, you must install the appropriate adapters in the slot locations that are shown in the 2145-SV1 columns. You can also install more adapters in the unused slots of the new node.
http://ibm.biz/portmapping| 2145-DH8, 2145-CG8 , or 2145-CF8 adapter slots | -fcportmap value | 2145-SV1 adapter slots | ||||||
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 5 | 3 | 4 | 6 | 7 | |
| 2x FC | default | 4x FC | ||||||
| 4x FC | default | 4x FC | ||||||
| 4x Ethernet | dh8:0+4 | 4x Ethernet | ||||||
| 2x FC | 2x FC | dh8:2+2:801 or dh8:2+2:80c * | 4x FC | |||||
| 2x FC | 4x Ethernet | dh8:2+4:80c ** | 4x FC | 4x Ethernet | ||||
| 4x FC | 2x Ethernet | default | 4x FC | 4x Ethernet | ||||
| 4x FC | 4x FC | default | 4x FC | 4x FC | ||||
| 2x FC | 2x FC | 2x FC | dh8:2+2+2:801 or dh8:2+2+2:80c * | 4x FC | 4x FC | |||
| 2x FC | 2x FC | 4x FC | dh8:2+2+0+4:801 or dh8:2+2+0+4:80c * | 4x FC | 4x FC | |||
| 2x FC | 2x FC | 4x Ethernet | dh8:2+2+0+4:801 or dh8:2+2+0+4:80c * | 4x FC | 4x Ethernet | |||
| 2x FC | 4x Ethernet | 2x FC | dh8:2+4+2:80c ** | 4x FC | 4x Ethernet | |||
| 4x FC | 2x FC | 2x FC | dh8:4+2+2 | 4x FC | 4x FC | |||
| 4x FC | 4x FC | 2x FC | default | 4x FC | 4x FC | 4x FC | ||
| 4x FC | 4x Ethernet | 2x FC | default | 4x FC | 4x Ethernet | 4x FC | ||
| 4x FC | 4x FC | 4x FC | default | 4x FC | 4x FC | 4x FC | ||
| 4x FC | 4x Ethernet | 4x FC | default | 4x FC | 4x Ethernet | 4x FC | ||
| 4x FC | 4x FC | 4x FC | dh8:4+4+0+4 | 4x FC | 4x FC | 4x FC | ||
| 4x FC | 4x Ethernet | 4x FC | dh8:4+4+0+4 | 4x FC | 4x Ethernet | 4x FC | ||
| 2x FC | 2x FC | 2x FC | 2x FC | dh8:2+2+2+2:801 or dh8:2+2+2+2:80c * | 4x FC | 4x FC | ||
| 2x FC | 4x Ethernet | 2x FC | 2x FC | dh8:2+4+2+2:80c ** | 4x FC | 4x Ethernet | 4x FC | |
| 4x FC | 4x FC | 2x FC | 2x FC | dh8:4+4+2+2 | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x Ethernet | 2x FC | 2x FC | dh8:4+4+2+2 | 4x FC | 4x Ethernet | 4x FC | |
| 4x FC | 4x FC | 4x FC | 2x FC | default | 4x FC | 4x FC | 4x FC | 4x FC |
| 4x FC | 4x Ethernet | 4x FC | 2x FC | default | 4x FC | 4x Ethernet | 4x FC | 4x FC |
| 4x FC | 4x FC | 4x FC | 4x FC | default | 4x FC | 4x FC | 4x FC | 4x FC |
| 4x FC | 4x Ethernet | 4x FC | 4x FC | default | 4x FC | 4x Ethernet | 4x FC | 4x FC |
| 4x FC | 4x FC | 4x FC | 4x Ethernet | default | 4x FC | 4x FC | 4x FC | 4x Ethernet |
|
Notes:
|
||||||||
Determining the port mapping
The following sections describe how to determine the individual port mappings that are listed in Table 1. The name of each section represents the value that you specify on the -fcportmap parameter of the chvpd command.
In each table, the new_adapter_location and new_adapter_port_id values are the adapter slot and port numbers in the 2145-SV1 node that are assigned the port mask position (fc_io_port_id) and WWPN value. You can also set port mappings for adapters that are not yet installed in the 2145-SV1 node. These mappings take effect if an adapter is later installed in that slot location. Each table shows one of the standard mappings and the chvpd command that is required to set the port mapping.
| Node | WWNN range |
|---|---|
| 2145-CG8 , 2145-CF8, or 2145-DH8 (in legacy mode) | 5005076801000000 - 500507680101FFFF |
| 2145-DH8 or 2145-SV1 (in legacy mode) | 500507680C000000 - 500507680C00FFFF |
| 2145-SV1 (in standard mode) | 500507680F000000 - 500507680F00FFFF |
Port map default
| fc_io_port_id | New 2145-SV1 port map | Existing node port map | WWPN values | ||||
|---|---|---|---|---|---|---|---|
| new_adapter_location | new_adapter_port_id | adapter_location | adapter_port_id | Legacy ( 2145-CG8 or 2145-CF8) | 2145-DH8 | 2145-SV1 | |
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx | 500507680C11xxxx | 500507680F01xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx | 500507680C12xxxx | 500507680F02xxxx |
| 3 | 3 | 3 | 1 | 3 | 500507680110xxxx | 500507680C13xxxx | 500507680F03xxxx |
| 4 | 3 | 4 | 1 | 4 | 500507680120xxxx | 500507680C14xxxx | 500507680F04xxxx |
| 5 | 4 | 1 | 2 | 1 | 500507680150xxxx | 500507680C21xxxx | 500507680F05xxxx |
| 6 | 4 | 2 | 2 | 2 | 500507680160xxxx | 500507680C22xxxx | 500507680F06xxxx |
| 7 | 4 | 3 | 2 | 3 | 500507680170xxxx | 500507680C23xxxx | 500507680F07xxxx |
| 8 | 4 | 4 | 2 | 4 | 500507680180xxxx | 500507680C24xxxx | 500507680F08xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680190xxxx | 500507680C31xxxx | 500507680F09xxxx |
| 10 | 6 | 2 | 3 | 2 | 5005076801A0xxxx | 500507680C32xxxx | 500507680F0Axxxx |
| 11 | 6 | 3 | 3 | 3 | 5005076801B0xxxx | 500507680C33xxxx | 500507680F0Bxxxx |
| 12 | 6 | 4 | 3 | 4 | 5005076801C0xxxx | 500507680C34xxxx | 500507680F0Cxxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680158xxxx | 500507680C51xxxx | 500507680F0Dxxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680168xxxx | 500507680C52xxxx | 500507680F0Exxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx | 500507680C53xxxx | 500507680F0Fxxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx | 500507680C54xxxx | 500507680F10xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap default
or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-23,44-24,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:0+4
Use this mapping if the existing 2145-DH8 node has slot 1 empty and a 4-port Ethernet adapter that is installed in slot 2.
The existing four ports are mapped to the four ports in slot 3 of the 2145-SV1 node. If you install a 4-port adapter in slot 4 of the 2145-SV1 node, the ports take the WWPN values that would have been used by slot 1 of the 2145-DH8 node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 2 | 1 | 500507680c21xxxx |
| 2 | 3 | 2 | 2 | 2 | 500507680c22xxxx |
| 3 | 3 | 3 | 2 | 3 | 500507680c23xxxx |
| 4 | 3 | 4 | 2 | 4 | 500507680c24xxxx |
| 5 | 4 | 1 | 1 | 1 | 500507680c11xxxx |
| 6 | 4 | 2 | 1 | 2 | 500507680c12xxxx |
| 7 | 4 | 3 | 1 | 3 | 500507680c13xxxx |
| 8 | 4 | 4 | 1 | 4 | 500507680c14xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 6 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 6 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 6 | 4 | 3 | 4 | 500507680c34xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port mapping on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:0+4
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-21,32-22,33-23,34-24,41-11,42-12,43-13,44-14,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:2+2:801
The existing four ports from the two FC adapters are mapped to the four ports in slot 3 of the 2145-SV1 node. If a 4-port adapter is installed in slot 4 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the 2145-DH8 node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 4 | 1 | 1 | 3 | 500507680110xxxx |
| 6 | 4 | 2 | 1 | 4 | 500507680120xxxx |
| 7 | 4 | 3 | 2 | 3 | 500507680150xxxx |
| 8 | 4 | 4 | 2 | 4 | 500507680160xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680190xxxx |
| 10 | 6 | 2 | 3 | 2 | 5005076801A0xxxx |
| 11 | 6 | 3 | 3 | 3 | 5005076801B0xxxx |
| 12 | 6 | 4 | 3 | 4 | 5005076801C0xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680158xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680168xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 31-11,32-12,33-24,34-23,41-13,42-14,43-21,44-22,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:2+2:80c
The existing four ports are mapped to the four ports in slot 3 of the 2145-SV1 node. If a 4-port adapter is installed in slot 4 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 1 | 1 | 3 | 500507680c13xxxx |
| 6 | 4 | 2 | 1 | 4 | 500507680c14xxxx |
| 7 | 4 | 3 | 2 | 3 | 500507680c23xxxx |
| 8 | 4 | 4 | 2 | 4 | 500507680c24xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 6 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 6 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 6 | 4 | 3 | 4 | 500507680c34xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,33-21,34-22,41-13,42-14,43-23,44-24,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:2+4:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
Port IDs 7 and 8 are assigned to the two additional FC ports in slot 3 of the 2145-SV1 node and take the WWPN values from the unused ports in slot 1 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 4 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 4 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 4 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 3 | 3 | 1 | 3 | 500507680c13xxxx |
| 8 | 3 | 4 | 1 | 4 | 500507680c14xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 6 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 6 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 6 | 4 | 3 | 4 | 500507680c34xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx-fcportmap dh8:2+4:80c
or
satask chvpd -wwnn 500507680c00xxxx-fcportmap 31-11,32-12,41-21,42-22,43-23,44-24,33-13,34-14,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:2+2+2:801
The existing six ports are mapped to the first six ports in slots 3 and 4 of the 2145-SV1 node. If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 4 | 1 | 3 | 1 | 500507680190xxxx |
| 6 | 4 | 2 | 3 | 2 | 5005076801a0xxxx |
| 7 | 4 | 3 | 3 | 3 | 5005076801b0xxxx |
| 8 | 4 | 4 | 3 | 4 | 5005076801c0xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680160xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680158xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680168xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx |
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+2:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 31-11,32-12,33-24,34-23,41-31,42-32,43-33,44-34,61-13,62-14,63-21,64-22,71-51,72-52,73-53,74-54
Port map dh8:2+2+2:80c
The existing six ports are mapped to the first six ports in slots 3 and 4 of the 2145-SV1 node. If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 1 | 3 | 1 | 500507680c31xxxx |
| 6 | 4 | 2 | 3 | 2 | 500507680c32xxxx |
| 7 | 4 | 3 | 3 | 3 | 500507680c33xxxx |
| 8 | 4 | 4 | 3 | 4 | 500507680c34xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680c24xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+2:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,33-21,34-22,41-31,42-32,43-33,44-34,61-13,62-14,63-23,64-24,71-51,72-52,73-53,74-54
Port map dh8:2+2+0+4:801
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node. If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the WWPN values from slot 3 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 4 | 1 | 5 | 1 | 500507680158xxxx |
| 6 | 4 | 2 | 5 | 2 | 500507680168xxxx |
| 7 | 4 | 3 | 5 | 3 | 500507680178xxxx |
| 8 | 4 | 4 | 5 | 4 | 500507680188xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680160xxxx |
| 13 | 7 | 1 | 3 | 1 | 500507680190xxxx |
| 14 | 7 | 2 | 3 | 2 | 5005076801a0xxxx |
| 15 | 7 | 3 | 3 | 3 | 5005076801b0xxxx |
| 16 | 7 | 4 | 3 | 4 | 5005076801c0xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+0+4:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 31-11,32-12,33-24,34-23,41-51,42-52,43-53,44-54,61-13,62-14,63-21,64-22,71-31,72-32,73-33,74-34
Port map dh8:2+2+0+4:80c
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node. If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the WWPN values from slot 3 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 1 | 5 | 1 | 500507680c51xxxx |
| 6 | 4 | 2 | 5 | 2 | 500507680c52xxxx |
| 7 | 4 | 3 | 5 | 3 | 500507680c53xxxx |
| 8 | 4 | 4 | 5 | 4 | 500507680c54xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680c24xxxx |
| 13 | 7 | 1 | 3 | 1 | 500507680c31xxxx |
| 14 | 7 | 2 | 3 | 2 | 500507680c32xxxx |
| 15 | 7 | 3 | 3 | 3 | 500507680c33xxxx |
| 16 | 7 | 4 | 3 | 4 | 500507680c34xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+0+4:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,33-21,34-22,41-51,42-52,43-53,44-54,61-13,62-14,63-23,64-24,71-31,72-32,73-33,74-34
Port map dh8:2+4+2:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 3 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 4 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 4 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 4 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 3 | 3 | 3 | 1 | 500507680c31xxxx |
| 8 | 3 | 4 | 3 | 2 | 500507680c32xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 6 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 6 | 4 | 3 | 4 | 500507680c34xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+4+2:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,41-21,42-22,43-23,44-24,33-31,34-32,61-13,62-14,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:4+2+2
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 2 and 3 of the existing node.
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx | 500507680c12xxxx |
| 3 | 3 | 3 | 1 | 3 | 500507680110xxxx | 500507680c13xxxx |
| 4 | 3 | 4 | 1 | 4 | 500507680120xxxx | 500507680c14xxxx |
| 5 | 4 | 1 | 2 | 1 | 500507680150xxxx | 500507680c21xxxx |
| 6 | 4 | 2 | 2 | 2 | 500507680160xxxx | 500507680c22xxxx |
| 7 | 4 | 3 | 3 | 1 | 500507680190xxxx | 500507680c31xxxx |
| 8 | 4 | 4 | 3 | 2 | 5005076801a0xxxx | 500507680c32xxxx |
| 9 | 6 | 1 | 2 | 3 | 500507680170xxxx | 500507680c23xxxx |
| 10 | 6 | 2 | 2 | 4 | 500507680180xxxx | 500507680c24xxxx |
| 11 | 6 | 3 | 3 | 3 | 5005076801b0xxxx | 500507680c33xxxx |
| 12 | 6 | 4 | 3 | 4 | 5005076801c0xxxx | 500507680c34xxxx |
| 13 | 7 | 1 | 5 | 1 | 500507680158xxxx | 500507680c51xxxx |
| 14 | 7 | 2 | 5 | 2 | 500507680168xxxx | 500507680c52xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+2+2
or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-31,44-32,61-23,62-24,63-33,64-34,71-51,72-52,73-53,74-54
Port map dh8:4+4+0+4
If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the WWPN values from slot 3 of the existing node.
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx | 500507680c12xxxx |
| 3 | 3 | 3 | 1 | 3 | 500507680110xxxx | 500507680c13xxxx |
| 4 | 3 | 4 | 1 | 4 | 500507680120xxxx | 500507680c14xxxx |
| 5 | 4 | 1 | 2 | 1 | 500507680150xxxx | 500507680c21xxxx |
| 6 | 4 | 2 | 2 | 2 | 500507680160xxxx | 500507680c22xxxx |
| 7 | 4 | 3 | 2 | 3 | 500507680170xxxx | 500507680c23xxxx |
| 8 | 4 | 4 | 2 | 4 | 500507680180xxxx | 500507680c24xxxx |
| 9 | 6 | 1 | 5 | 1 | 500507680158xxxx | 500507680c51xxxx |
| 10 | 6 | 2 | 5 | 2 | 500507680168xxxx | 500507680c52xxxx |
| 11 | 6 | 3 | 5 | 3 | 500507680178xxxx | 500507680c53xxxx |
| 12 | 6 | 4 | 5 | 4 | 500507680188xxxx | 500507680c54xxxx |
| 13 | 7 | 1 | 3 | 1 | 500507680190xxxx | 500507680c31xxxx |
| 14 | 7 | 2 | 3 | 2 | 5005076801a0xxxx | 500507680c32xxxx |
| 15 | 7 | 3 | 3 | 3 | 5005076801b0xxxx | 500507680c33xxxx |
| 16 | 7 | 4 | 3 | 4 | 5005076801c0xxxx | 500507680c34xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+4+0+4
or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-23,44-24,61-51,62-52,63-53,64-54,71-31,72-32,73-33,74-34
Port map dh8:2+2+2+2:801
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node. If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the unused WWPN values from slots 3 and 5 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 4 | 1 | 3 | 1 | 500507680190xxxx |
| 6 | 4 | 2 | 3 | 2 | 5005076801a0xxxx |
| 7 | 4 | 3 | 5 | 1 | 500507680158xxxx |
| 8 | 4 | 4 | 5 | 2 | 500507680168xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680160xxxx |
| 13 | 7 | 1 | 3 | 3 | 5005076801b0xxxx |
| 14 | 7 | 2 | 3 | 4 | 5005076801c0xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+2+2:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 31-11,32-12,33-24,34-23,41-31,42-32,43-51,44-52,61-13,62-14,63-21,64-22,71-33,72-34,73-53,74-54
Port map dh8:2+2+2+2:80c
If a 4-port adapter is installed in slot 6 of the 2145-SV1 node, it takes the unused WWPN values from slots 1 and 2 of the existing node. If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the unused WWPN values from slots 3 and 5 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 3 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 3 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 1 | 3 | 1 | 500507680c31xxxx |
| 6 | 4 | 2 | 3 | 2 | 500507680c32xxxx |
| 7 | 4 | 3 | 5 | 1 | 500507680c51xxxx |
| 8 | 4 | 4 | 5 | 2 | 500507680c52xxxx |
| 9 | 6 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 6 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 6 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 6 | 4 | 2 | 4 | 500507680c24xxxx |
| 13 | 7 | 1 | 3 | 3 | 500507680c33xxxx |
| 14 | 7 | 2 | 3 | 4 | 500507680c34xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+2+2:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,33-21,34-22,41-31,42-32,43-51,44-52,61-13,62-14,63-23,64-24,71-33,72-34,73-53,74-54
Port dh8:2+4+2+2:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
Port IDs 11 and 12 are assigned to the third and fourth ports in slot 3 of the 2145-SV1 node take the WWPN values from the unused ports in slot 1 of the existing node. If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the unused WWPN values from slots 3 and 5 of the existing node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 3 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 4 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 4 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 4 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 4 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 6 | 1 | 3 | 1 | 500507680c31xxxx |
| 8 | 6 | 2 | 3 | 2 | 500507680c32xxxx |
| 9 | 6 | 3 | 5 | 1 | 500507680c51xxxx |
| 10 | 6 | 4 | 5 | 2 | 500507680c52xxxx |
| 11 | 3 | 3 | 1 | 3 | 500507680c13xxxx |
| 12 | 3 | 4 | 1 | 4 | 500507680c14xxxx |
| 13 | 7 | 1 | 3 | 3 | 500507680c33xxxx |
| 14 | 7 | 2 | 3 | 4 | 500507680c34xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680c53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680c54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+4+2+2:80c
or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 31-11,32-12,41-21,42-22,43-23,44-24,61-31,62-32,63-51,64-52,33-13,34-14,71-33,72-34,73-53,74-54
Port map dh8:4+4+2+2
If a 4-port adapter is installed in slot 7 of the 2145-SV1 node, it takes the unused WWPN values from slots 3 and 5 of the existing node.
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 3 | 1 | 1 | 1 | 500507680140xxxx | 500507680C11xxxx |
| 2 | 3 | 2 | 1 | 2 | 500507680130xxxx | 500507680C12xxxx |
| 3 | 3 | 3 | 1 | 3 | 500507680110xxxx | 500507680C13xxxx |
| 4 | 3 | 4 | 1 | 4 | 500507680120xxxx | 500507680C14xxxx |
| 5 | 4 | 1 | 2 | 1 | 500507680150xxxx | 500507680C21xxxx |
| 6 | 4 | 2 | 2 | 2 | 500507680160xxxx | 500507680C22xxxx |
| 7 | 4 | 3 | 2 | 3 | 500507680170xxxx | 500507680C23xxxx |
| 8 | 4 | 4 | 2 | 4 | 500507680180xxxx | 500507680C24xxxx |
| 9 | 6 | 1 | 3 | 1 | 500507680190xxxx | 500507680C31xxxx |
| 10 | 6 | 2 | 3 | 2 | 5005076801A0xxxx | 500507680C32xxxx |
| 11 | 6 | 3 | 5 | 1 | 500507680158xxxx | 500507680C51xxxx |
| 12 | 6 | 4 | 5 | 2 | 500507680168xxxx | 500507680C52xxxx |
| 13 | 7 | 1 | 3 | 3 | 5005076801b0xxxx | 500507680C33xxxx |
| 14 | 7 | 2 | 3 | 4 | 5005076801c0xxxx | 500507680C34xxxx |
| 15 | 7 | 3 | 5 | 3 | 500507680178xxxx | 500507680C53xxxx |
| 16 | 7 | 4 | 5 | 4 | 500507680188xxxx | 500507680C54xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+4+2+2
or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-23,44-24,61-31,62-32,63-51,64-52,71-33,72-34,73-53,74-54
Setting the mapping manually
The fcportmap value is built from the slot and location of each port in the 2145-SV1 node and the slot and port locations from the existing node. To manually set the port mapping, perform the following steps.
Template to manually set fcportmap values
You can use Table 22 to record information about the existing node and the new 2145-SV1 node.
| fc_io_port_id | New 2145-SV1 node | Existing node | WWPN
|
||
|---|---|---|---|---|---|
| adapter_location A | adapter_port_id B | adapter_location C | adapter_port_id D | ||
| 1 | 500507680__ __ __ ________ | ||||
| 2 | 500507680__ __ __ ________ | ||||
| 3 | 500507680__ __ __ ________ | ||||
| 4 | 500507680__ __ __ ________ | ||||
| 5 | 500507680__ __ __ ________ | ||||
| 6 | 500507680__ __ __ ________ | ||||
| 7 | 500507680__ __ __ ________ | ||||
| 8 | 500507680__ __ __ ________ | ||||
| 9 | 500507680__ __ __ ________ | ||||
| 10 | 500507680__ __ __ ________ | ||||
| 11 | 500507680__ __ __ ________ | ||||
| 12 | 500507680__ __ __ ________ | ||||
| 13 | 500507680__ __ __ ________ | ||||
| 14 | 500507680__ __ __ ________ | ||||
| 15 | 500507680__ __ __ ________ | ||||
| 16 | 500507680__ __ __ ________ | ||||