Setting the Fibre Channel port mapping: 2145-SV2 or 2145-SA2
When you upgrade to a 2145-SV2 or 2145-SA2 node, you can preserve the port layout and worldwide port names (WWPNs) from the legacy node. To do so, you can change which physical ports are mapped to particular Fibre Channel I/O ports on the 2145-SV2 or 2145-SA2 node.
Determining adapter slot locations
In most cases, you can use one of the standard port mappings when you are replacing a SAN Volume Controller 2145-DH8 or 2145-SV1 that was previously upgraded from an earlier node type.
If you set the pre-defined port mapping in the -fcportmap column, you must install the appropriate adapters in the slot locations that are shown in the 2145-SV2 or 2145-SA2 columns. You can also install more adapters in the unused slots of the new node.
Note that 2145-SV2 and 2145-SA2 nodes do not support Fibre Channel over Ethernet (FCoE) connections. If your existing system uses FCoE then you can assign those WWPNs to native Fibre Channel ports in the new nodes.
http://ibm.biz/portmappingNote that 2145-SV2 and 2145-SA2 nodes support a maximum of 12 Fibre Channel ports. If your existing system has more than 12 Fibre Channel and Fibre Channel over Ethernet ports, only the first 12 are covered by the pre-defined mappings.
| 2145-DH8 legacy adapter slots | -fcportmap value | 2145-SV2 or 2145-SA2 adapter slots | |||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 5 | 1 | 2 | 3 | |
| 2x FC | default | 4x FC | |||||
| 4x FC | default | 4x FC | |||||
| 4x FCoE | dh8:0+4 | 4x FC | |||||
| 2x FC | 2x FC | dh8:2+2:801 or dh8:2+2:80c * | 4x FC | ||||
| 2x FC | 4x FCoE | dh8:2+4:80c ** | 4x FC | 4x FC | |||
| 4x FC | 4x FCoE | default | 4x FC | 4x FC | |||
| 4x FC | 4x FC | default | 4x FC | 4x FC | |||
| 2x FC | 2x FC | 2x FC | dh8:2+2+2:801 or dh8:2+2+2:80c * | 4x FC | 4x FC | ||
| 2x FC | 2x FC | 4x FC | dh8:2+2+0+4:801 or dh8:2+2+0+4:80c * | 4x FC | 4x FC | ||
| 2x FC | 2x FC | 4x FCoE | dh8:2+2+0+4:801 or dh8:2+2+0+4:80c * | 4x FC | 4x FC | ||
| 2x FC | 4x FCoE | 2x FC | dh8:2+4+2:80c ** | 4x FC | 4x FC | ||
| 4x FC | 2x FC | 2x FC | dh8:4+2+2 | 4x FC | 4x FC | ||
| 4x FC | 4x FC | 2x FC | default | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x FCoE | 2x FC | default | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x FC | 4x FC | default | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x FCoE | 4x FC | default | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x FC | 4x FC | dh8:4+4+0+4 | 4x FC | 4x FC | 4x FC | |
| 4x FC | 4x FCoE | 4x FC | dh8:4+4+0+4 | 4x FC | 4x FC | 4x FC | |
| 2x FC | 2x FC | 2x FC | 2x FC | dh8:2+2+2+2:801 or dh8:2+2+2+2:80c * | 4x FC | 4x FC | |
| 2x FC | 4x FCoE | 2x FC | 2x FC | dh8:2+4+2+2:80c ** | 4x FC | 4x FC | 4x FC |
| 4x FC | 4x FC | 2x FC | 2x FC | dh8:4+4+2+2 | 4x FC | 4x FC | 4x FC |
| 4x FC | 4x FCoE | 2x FC | 2x FC | dh8:4+4+2+2 | 4x FC | 4x FC | 4x FC |
|
Notes:
|
|||||||
Determining the port mapping
In each table, the new_adapter_location and new_adapter_port_id values are the adapter slot and port numbers in the 2145-SV2 or 2145-SA2 node that are assigned the port mask position (fc_io_port_id) and WWPN value. You can also set port mappings for adapters that are not yet installed in the 2145-SV2 or 2145-SA2 node. These mappings take effect if an adapter is later installed in that slot location. Each table shows one of the standard mappings and the chvpd command that is required to set the port mapping.
In the tables below new_adapter_location and new_adapter_port_id are the slot and port numbers in the new node which will be assigned the fc_io_port_id and WWPN. Each table shows one of the standard mappings with the command to set it. You can set mappings for adapters that are not yet installed and these mappings will take effect if an adapter is ever installed in that location.
Your existing node could have a WWNN in one of three ranges depending on the hardware type to which the WWNN was first assigned.
| WWNN range | Node |
|---|---|
5005076801000000 - 500507680101FFFF |
Any* |
500507680C000000 - 500507680C00FFFF |
2145-DH8, 2145-SV1 *, 2145-SV2*, 2145-SA2* |
500507680F000000 - 500507680F00FFFF |
2145-SV1 , 2145-SV2*, 2145-SA2* |
5005076810000000 - 500507681000FFFF |
2145-SV2, 2145-SA2 |
| * Not this node's standard WWNN range (supported for nondisruptive upgrade from legacy nodes) | |
Port map default
| fc_io_port_id | New | Legacy | WWPN values | ||||
|---|---|---|---|---|---|---|---|
| new_adapter_location | new_adapter_port_id | adapter_location | adapter_port_id | ||||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx | 500507680C11xxxx | 500507680F01xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx | 500507680C12xxxx | 500507680F02xxxx |
| 3 | 1 | 3 | 1 | 3 | 500507680110xxxx | 500507680C13xxxx | 500507680F03xxxx |
| 4 | 1 | 4 | 1 | 4 | 500507680120xxxx | 500507680C14xxxx | 500507680F04xxxx |
| 5 | 2 | 1 | 2 | 1 | 500507680150xxxx | 500507680C21xxxx | 500507680F05xxxx |
| 6 | 2 | 2 | 2 | 2 | 500507680160xxxx | 500507680C22xxxx | 500507680F06xxxx |
| 7 | 2 | 3 | 2 | 3 | 500507680170xxxx | 500507680C23xxxx | 500507680F07xxxx |
| 8 | 2 | 4 | 2 | 4 | 500507680180xxxx | 500507680C24xxxx | 500507680F08xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680190xxxx | 500507680C31xxxx | 500507680F09xxxx |
| 10 | 3 | 2 | 3 | 2 | 5005076801A0xxxx | 500507680C32xxxx | 500507680F0Axxxx |
| 11 | 3 | 3 | 3 | 3 | 5005076801B0xxxx | 500507680C33xxxx | 500507680F0Bxxxx |
| 12 | 3 | 4 | 3 | 4 | 5005076801C0xxxx | 500507680C34xxxx | 500507680F0Cxxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap default
or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 11-11,12-12,13-13,14-14,21-21,22-22,23-23,24-24,31-31,32-32,33-33,34-34
Port map dh8:0+4
Use this mapping if the legacy node has slot 1 empty and a 4-port FCoE adapter that is installed in slot 2.
The existing four ports are mapped to the four ports in slot 1 of the 2145-SV2 or 2145-SA2 node. If you install a 4-port adapter in slot 2 of the 2145-SV2 or 2145-SA2 node, the ports take the WWPN values that would have been used by slot 1 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 2 | 1 | 500507680c21xxxx |
| 2 | 1 | 2 | 2 | 2 | 500507680c22xxxx |
| 3 | 1 | 3 | 2 | 3 | 500507680c23xxxx |
| 4 | 1 | 4 | 2 | 4 | 500507680c24xxxx |
| 5 | 2 | 1 | 1 | 1 | 500507680c11xxxx |
| 6 | 2 | 2 | 1 | 2 | 500507680c12xxxx |
| 7 | 2 | 3 | 1 | 3 | 500507680c13xxxx |
| 8 | 2 | 4 | 1 | 4 | 500507680c14xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 3 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 3 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 3 | 4 | 3 | 4 | 500507680c34xxxx |
To establish this port mapping on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:0+4or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-21,12-22,13-23,14-24,21-11,22-12,23-13,24-14,31-31,32-32,33-33,34-34Port map dh8:2+2:801
The existing four ports from the two FC adapters are mapped to the four ports in slot 1 of the 2145-SV2 or 2145-SA2 node. If a 4-port adapter is installed in slot 2 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Legacy | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 2 | 1 | 1 | 3 | 500507680110xxxx |
| 6 | 2 | 2 | 1 | 4 | 500507680120xxxx |
| 7 | 2 | 3 | 2 | 3 | 500507680150xxxx |
| 8 | 2 | 4 | 2 | 4 | 500507680160xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680190xxxx |
| 10 | 3 | 2 | 3 | 2 | 5005076801A0xxxx |
| 11 | 3 | 3 | 3 | 3 | 5005076801B0xxxx |
| 12 | 3 | 4 | 3 | 4 | 5005076801C0xxxx |
To establish this port map on the 2145-SV1 node, enter one of the following chvpd commands.
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 11-11,12-12,13-24,14-23,21-13,22-14,23-21,24-22,31-31,32-32,33-33,34-34Port map dh8:2+2:80c
The existing four ports from the two FC adapters are mapped to the four ports in slot 1 of the 2145-SV2 or 2145-SA2 node. If a 4-port adapter is installed in slot 2 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Legacy | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 1 | 1 | 3 | 500507680c13xxxx |
| 6 | 2 | 2 | 1 | 4 | 500507680c14xxxx |
| 7 | 2 | 3 | 2 | 3 | 500507680c23xxxx |
| 8 | 2 | 4 | 2 | 4 | 500507680c24xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 3 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 3 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 3 | 4 | 3 | 4 | 500507680c34xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2:80cor
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,13-21,14-22,21-13,22-14,23-23,24-24,31-31,32-32,33-33,34-34
Port map dh8:2+4:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
Port IDs 7 and 8 are assigned to the two additional FC ports in slot 3 of the 2145-SV2 or 2145-SA2 node and take the WWPN values from the unused ports in slot 1 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 2 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 2 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 2 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 1 | 3 | 1 | 3 | 500507680c13xxxx |
| 8 | 1 | 4 | 1 | 4 | 500507680c14xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680c31xxxx |
| 10 | 3 | 2 | 3 | 2 | 500507680c32xxxx |
| 11 | 3 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 3 | 4 | 3 | 4 | 500507680c34xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx-fcportmap dh8:2+4:80c or
satask chvpd -wwnn 500507680c00xxxx-fcportmap 11-11,12-12,21-21,22-22,23-23,24-24,13-13,14-14,31-31,32-32,33-33,34-34Port map dh8:2+2+2:801
The existing six ports are mapped to the first six ports in slots 1 and 2 of the 2145-SV2 or 2145-SA2 node. If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 2 | 1 | 3 | 1 | 500507680190xxxx |
| 6 | 2 | 2 | 3 | 2 | 5005076801a0xxxx |
| 7 | 2 | 3 | 3 | 3 | 5005076801b0xxxx |
| 8 | 2 | 4 | 3 | 4 | 5005076801c0xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680160xxxx |
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+2:801 or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 11-11,12-12,13-24,14-23,21-31,22-32,23-33,24-34,31-13,32-14,33-21,34-22
Port map dh8:2+2+2:80c
The existing six ports are mapped to the first six ports in slots 1 and 2 of the 2145-SV2 or 2145-SA2 node. If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 1 | 3 | 1 | 500507680c31xxxx |
| 6 | 2 | 2 | 3 | 2 | 500507680c32xxxx |
| 7 | 2 | 3 | 3 | 3 | 500507680c33xxxx |
| 8 | 2 | 4 | 3 | 4 | 500507680c34xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680c24xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+2:80c or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,13-21,14-22,21-31,22-32,23-33,24-34,31-13,32-14,33-23,34-24
Port map dh8:2+2+0+4:801
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 2 | 1 | 5 | 1 | 500507680158xxxx |
| 6 | 2 | 2 | 5 | 2 | 500507680168xxxx |
| 7 | 2 | 3 | 5 | 3 | 500507680178xxxx |
| 8 | 2 | 4 | 5 | 4 | 500507680188xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680160xxxx |
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+0+4:801
or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 11-11,12-12,13-24,14-23,21-51,22-52,23-53,24-54,31-13,32-14,33-21,34-22
Port map dh8:2+2+0+4:80c
If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 1 | 5 | 1 | 500507680c51xxxx |
| 6 | 2 | 2 | 5 | 2 | 500507680c52xxxx |
| 7 | 2 | 3 | 5 | 3 | 500507680c53xxxx |
| 8 | 2 | 4 | 5 | 4 | 500507680c54xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680c24xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+0+4:80c or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,13-21,14-22,21-51,22-52,23-53,24-54,31-13,32-14,33-23,34-24Port map dh8:2+4+2:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 3 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 2 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 2 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 2 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 1 | 3 | 3 | 1 | 500507680c31xxxx |
| 8 | 1 | 4 | 3 | 2 | 500507680c32xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 3 | 3 | 3 | 3 | 500507680c33xxxx |
| 12 | 3 | 4 | 3 | 4 | 500507680c34xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+4+2:80c or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,21-21,22-22,23-23,24-24,13-31,14-32,31-13,32-14,33-33,34-34 Port map dh8:4+2+2
If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 2 and 3 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx | 500507680c12xxxx |
| 3 | 1 | 3 | 1 | 3 | 500507680110xxxx | 500507680c13xxxx |
| 4 | 1 | 4 | 1 | 4 | 500507680120xxxx | 500507680c14xxxx |
| 5 | 2 | 1 | 2 | 1 | 500507680150xxxx | 500507680c21xxxx |
| 6 | 2 | 2 | 2 | 2 | 500507680160xxxx | 500507680c22xxxx |
| 7 | 2 | 3 | 3 | 1 | 500507680190xxxx | 500507680c31xxxx |
| 8 | 2 | 4 | 3 | 2 | 5005076801a0xxxx | 500507680c32xxxx |
| 9 | 3 | 1 | 2 | 3 | 500507680170xxxx | 500507680c23xxxx |
| 10 | 3 | 2 | 2 | 4 | 500507680180xxxx | 500507680c24xxxx |
| 11 | 3 | 3 | 3 | 3 | 5005076801b0xxxx | 500507680c33xxxx |
| 12 | 3 | 4 | 3 | 4 | 5005076801c0xxxx | 500507680c34xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+2+2 or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 11-11,12-12,13-13,14-14,21-21,22-22,23-31,24-32,31-23,32-24,33-33,34-34 Port map dh8:4+4+0+4
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx | 500507680c12xxxx |
| 3 | 1 | 3 | 1 | 3 | 500507680110xxxx | 500507680c13xxxx |
| 4 | 1 | 4 | 1 | 4 | 500507680120xxxx | 500507680c14xxxx |
| 5 | 2 | 1 | 2 | 1 | 500507680150xxxx | 500507680c21xxxx |
| 6 | 2 | 2 | 2 | 2 | 500507680160xxxx | 500507680c22xxxx |
| 7 | 2 | 3 | 2 | 3 | 500507680170xxxx | 500507680c23xxxx |
| 8 | 2 | 4 | 2 | 4 | 500507680180xxxx | 500507680c24xxxx |
| 9 | 3 | 1 | 5 | 1 | 500507680158xxxx | 500507680c51xxxx |
| 10 | 3 | 2 | 5 | 2 | 500507680168xxxx | 500507680c52xxxx |
| 11 | 3 | 3 | 5 | 3 | 500507680178xxxx | 500507680c53xxxx |
| 12 | 3 | 4 | 5 | 4 | 500507680188xxxx | 500507680c54xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+4+0+4 or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 11-11,12-12,13-13,14-14,21-21,22-22,23-23,24-24,31-51,32-52,33-53,34-54 Port map dh8:2+2+2+2:801
If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680180xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680170xxxx |
| 5 | 2 | 1 | 3 | 1 | 500507680190xxxx |
| 6 | 2 | 2 | 3 | 2 | 5005076801a0xxxx |
| 7 | 2 | 3 | 5 | 1 | 500507680158xxxx |
| 8 | 2 | 4 | 5 | 2 | 500507680168xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680110xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680120xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680150xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680160xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 50050768010xxxxx -fcportmap dh8:2+2+2+2:801 or
satask chvpd -wwnn 50050768010xxxxx -fcportmap 11-11,12-12,13-24,14-23,21-31,22-32,23-51,24-52,31-13,32-14,33-21,34-22Port map dh8:2+2+2+2:80c
If a 4-port adapter is installed in slot 3 of the 2145-SV2 or 2145-SA2 node, it takes the unused WWPN values from slots 1 and 2 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 1 | 3 | 2 | 1 | 500507680c21xxxx |
| 4 | 1 | 4 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 1 | 3 | 1 | 500507680c31xxxx |
| 6 | 2 | 2 | 3 | 2 | 500507680c32xxxx |
| 7 | 2 | 3 | 5 | 1 | 500507680c51xxxx |
| 8 | 2 | 4 | 5 | 2 | 500507680c52xxxx |
| 9 | 3 | 1 | 1 | 3 | 500507680c13xxxx |
| 10 | 3 | 2 | 1 | 4 | 500507680c14xxxx |
| 11 | 3 | 3 | 2 | 3 | 500507680c23xxxx |
| 12 | 3 | 4 | 2 | 4 | 500507680c24xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+2+2+2:80c or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,13-21,14-22,21-31,22-32,23-51,24-52,31-13,32-14,33-23,34-24Port dh8:2+4+2+2:80c
801version. If you have this adapter configuration and a WWNN from a previous node type, contact your IBM service support representative.
Port IDs 11 and 12 are assigned to the third and fourth ports in slot 3 of the 2145-SV2 or 2145-SA2 node take the WWPN values from the unused ports in slot 1 of the legacy node.
| fc_io_port_id | New | Existing | WWPN | ||
|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | ||
| 1 | 1 | 1 | 1 | 1 | 500507680c11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680c12xxxx |
| 3 | 2 | 1 | 2 | 1 | 500507680c21xxxx |
| 4 | 2 | 2 | 2 | 2 | 500507680c22xxxx |
| 5 | 2 | 3 | 2 | 3 | 500507680c23xxxx |
| 6 | 2 | 4 | 2 | 4 | 500507680c24xxxx |
| 7 | 3 | 1 | 3 | 1 | 500507680c31xxxx |
| 8 | 3 | 2 | 3 | 2 | 500507680c32xxxx |
| 9 | 3 | 3 | 5 | 1 | 500507680c51xxxx |
| 10 | 3 | 4 | 5 | 2 | 500507680c52xxxx |
| 11 | 1 | 3 | 1 | 3 | 500507680c13xxxx |
| 12 | 1 | 4 | 1 | 4 | 500507680c14xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680c00xxxx -fcportmap dh8:2+4+2+2:80c or
satask chvpd -wwnn 500507680c00xxxx -fcportmap 11-11,12-12,21-21,22-22,23-23,24-24,31-31,32-32,33-51,34-52,13-13,14-14 Port map dh8:4+4+2+2
| fc_io_port_id | New | Existing | WWPN | WWPN | ||
|---|---|---|---|---|---|---|
| adapter_location | adapter_port_id | adapter_location | adapter_port_id | |||
| 1 | 1 | 1 | 1 | 1 | 500507680140xxxx | 500507680C11xxxx |
| 2 | 1 | 2 | 1 | 2 | 500507680130xxxx | 500507680C12xxxx |
| 3 | 1 | 3 | 1 | 3 | 500507680110xxxx | 500507680C13xxxx |
| 4 | 1 | 4 | 1 | 4 | 500507680120xxxx | 500507680C14xxxx |
| 5 | 2 | 1 | 2 | 1 | 500507680150xxxx | 500507680C21xxxx |
| 6 | 2 | 2 | 2 | 2 | 500507680160xxxx | 500507680C22xxxx |
| 7 | 2 | 3 | 2 | 3 | 500507680170xxxx | 500507680C23xxxx |
| 8 | 2 | 4 | 2 | 4 | 500507680180xxxx | 500507680C24xxxx |
| 9 | 3 | 1 | 3 | 1 | 500507680190xxxx | 500507680C31xxxx |
| 10 | 3 | 2 | 3 | 2 | 5005076801A0xxxx | 500507680C32xxxx |
| 11 | 3 | 3 | 5 | 1 | 500507680158xxxx | 500507680C51xxxx |
| 12 | 3 | 4 | 5 | 2 | 500507680168xxxx | 500507680C52xxxx |
To establish this port map on the 2145-SV2 or 2145-SA2 node, enter one of the following chvpd commands.
satask chvpd -wwnn 500507680x0xxxxx -fcportmap dh8:4+4+2+2 or
satask chvpd -wwnn 500507680x0xxxxx -fcportmap 11-11,12-12,13-13,14-14,21-21,22-22,23-51,24-52
Setting the mapping manually
The fcportmap value is built from the slot and location of each port in the 2145-SV2 or 2145-SA2 node and the slot and port locations from the legacy node. To manually set the port mapping, perform the following steps.
Template to manually set fcportmap values
| fc_io_port_id | New 2145-SV2 or 2145-SA2 node | Existing node | WWPN
|
||
|---|---|---|---|---|---|
| adapter_location A | adapter_port_id B | adapter_location C | adapter_port_id D | ||
| 1 | 500507680__ __ __ ________ | ||||
| 2 | 500507680__ __ __ ________ | ||||
| 3 | 500507680__ __ __ ________ | ||||
| 4 | 500507680__ __ __ ________ | ||||
| 5 | 500507680__ __ __ ________ | ||||
| 6 | 500507680__ __ __ ________ | ||||
| 7 | 500507680__ __ __ ________ | ||||
| 8 | 500507680__ __ __ ________ | ||||
| 9 | 500507680__ __ __ ________ | ||||
| 10 | 500507680__ __ __ ________ | ||||
| 11 | 500507680__ __ __ ________ | ||||
| 12 | 500507680__ __ __ ________ | ||||