Removing and replacing the cover of the canister: 2145-SV2 and 2145-SA2
To complete a service procedure, you may need to remove and replace the cover of the
canister.
About this task
No tools are required to complete this task. Do not remove or loosen any screws.
The cover of the canister can be removed only after the canister is removed from the control
enclosure.
Procedure
Remove the canister from the control enclosure.
Removing the cover
Place the canister on a flat, level work surface. The release levers should be facing you and
the cover should be facing upwards.
Open the cover of the canister by depressing the recessed, blue touch points on the lid
( 1 ) and sliding the lid away from you before lifting the lid from the
canister ( 2 ), as shown in Figure 1.
Figure 1. Removing the canister cover
Replacing the cover
Align the lid with the latching points and lower it onto the canister as shown in Figure 2, so that it lies flat on the canister
Figure 2. Replacing the canister cover
Slide the cover until the latch clicks and the rear of the lid fully engages with the
rear of the canister.