Fibre Channel LEDs
The Fibre Channel LEDs indicate the status of the Fibre Channel ports on the SAN Volume Controller 2145-SV1 node.
The SAN Volume Controller 2145-SV1 uses two LEDs per Fibre Channel port, which are located directly under the port. The following figure shows the location of the LEDs.

- 1 Green LEDs
- 2 Amber LEDs
The following table lists the link status values for the Fibre Channel LEDs.
| Green LED | Amber LED | Meaning |
|---|---|---|
| Off | Off | One of the following situations is in effect:
|
| Off | On | The port is configured, but the link is not detected at the transport layer. This situation is the result of the port not being connected or of a failed link negotiation with the switch. |
| On | Off | The link is up and running at the expected port speed. This display does not necessarily imply logical connectivity, that is, completion of FLOGI or FIP. |
| On | On | The link is up, but running at a degraded speed. |