You might need to replace the small form-factor pluggable (SFP) transceiver when a failure occurs on a
single Fibre Channel or 10 Gbps Ethernet link (applicable to Fibre Channel over Ethernet personality enabled 10 Gbps Ethernet
link).
Before you begin
The following
items can indicate that a single Fibre Channel or 10 Gbps Ethernet link failed:
- The Fibre Channel port status on the front panel of the node
- The Fibre Channel status light-emitting diodes (LEDs) at the rear of the node
- An error that indicates that a single port
failed (703, 723).
About this task
Use only IBM® supported 10 Gb SFP transceivers with the SAN Volume Controller 2145-DH8
. Using any other
SFP transceivers can lead to unexpected
system behavior.
Copper DAC is not supported by these 10 Gb ports. The SFP transceiver replacement in a 10 Gbps
Ethernet adapter port is governed by the following rules:
- An existing 10 Gbps SFP transceiver
that is replaced with a new 10 Gbps SFP transceiver: The 10 Gbps Ethernet
adapter port detects a new SFP transceiver and becomes operational
immediately.
- If the 10 Gbps Ethernet adapter port detects a new SFP transceiver and becomes operational
immediately, the port has an incorrect SFP transceiver since the last reboot.
The SFP transceiver is then replaced
with the correct 10 Gbps .SFP transceiver This situation can occur
with an incompatible SFP transceiver
(8 Gbps SFP or 4 Gbps SFP) that is inserted in the 10 Gbps Ethernet adapter port.
- The node requires a reboot for detecting the new SFP transceiver. The new SFP transceiver will be operational
only after reboot (no DMP is produced).
- The 10 Gbps Ethernet adapter port contains no SFP transceiver since the last reboot
and the correct 10 Gb SFP transceiver
is installed:
- System reboot is required for detecting the new SFP transceiver.
Procedure
Attempt each of these actions, in the following order, until the failure is
fixed.
-
Ensure that the Fibre Channel or 10G Ethernet cable is securely
connected at each end.
-
Replace the Fibre Channel or 10G Ethernet cable.
-
Replace the SFP transceiver for the
failing port on the node.
Note: If the system is supported by both longwave SFP transceivers and shortwave SFP transceivers. You must replace an
SFP transceiver with the same type
of SFP transceiver. If the SFP transceiver to replace is a longwave
SFP transceiver, for example, you
must provide a suitable replacement. Removing the wrong SFP transceiver might result in loss of
data access.
-
Perform the Fibre Channel switch service
procedures for a failing Fibre Channel link. This procedure might involve replacing the
SFP transceiver at the
switch.Perform the Fibre Channel switch or FCF service
procedures for a failing Fibre Channel or 10 Gbps Ethernet with Fibre Channel over
Ethernet personality enabled link. This procedure might involve replacing the SFP transceiver at the
switch.
-
Replace the Fibre Channel adapter or Fibre Channel over Ethernet adapter
on the node.