You can replace the 240 VA safety cover on a SAN Volume Controller 2145-DH8 node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
or
or
Take precautions to avoid damage from static electricity.
Wear an anti-static wrist strap and use a static-protected mat or
surface.
About this task
This service action assumes:
The node is turned off. If you must turn off the node, ensure that
hosts will not lose access to data in volumes, as described in MAP 5350: Powering off a node.
The power cables are disconnected.
The top cover is removed.
The air baffle is removed.
The PCI express rise-card assemblies are removed.
To replace the 240 VA safety cover, complete the following steps.
Procedure
Line up and insert the tabs on the bottom of the safety cover into the slots on the system
board, as shown in Figure 1.
Figure 1. Replacing the SAN Volume Controller 2145-DH8 240 VA safety cover
Slide the safety cover toward the back of the SAN Volume Controller 2145-DH8 until
it is secure.
Connect the power cables to the connector in front of the
safety cover.
Install the screw into the safety cover.
Replace the PCI express rise-card assemblies.
Replace the air baffle.
Replace the top cover.
If you removed the node from the rack, replace the node
in the rack.
If you removed any Fibre Channel or Ethernet cables, using
the labels that you placed on each cable, replace them in the same
ports from which they were removed.
If you removed the power cords, replace the power cords
and the cable-retention brackets.
Lift the locking levers ( 1 in Figure 2) on the slide
rails and push the server 2 all the way
into the rack until it clicks into place.