Verifying the SAN Volume Controller 2145-SV1
installation
You must verify the installation after the installation has
completed.
Before you begin
This task shows you how to verify the installation after you install the system in
the rack and connect it to the storage area network (SAN) and the
Ethernet.
Note: If at any point the system does not operate as described, see MAP 5000: Start, unless a
different maintenance analysis procedure (MAP) is specified.
Procedure
To verify the installation, complete the following steps.
Connect power supply 1 and power supply 2 to a live AC supply.
The SAN Volume Controller node begins to
power on. The Power LED should be solidly on after a few seconds, but if it continues to
flash after 1 minute, press the power-control button. If the LED is not illuminated, see
MAP 5000: Start to
repair the problem.
Note: You do not need to install any software. The node boots
automatically.
The SAN Volume Controller 2145-SV1 runs
an extended series of power-on self-tests. The node might appear to be idle for up to 5
minutes after it powers on.
Figure 1 shows the controls and indicators
on the front panel that verify the installation. Figure 2 is a close-up view of the operator-information panel.
Figure 1. SAN Volume Controller 2145-SV1
front panel
1 Boot drive activity LED
2 Boot drive status LED
3 Pullout tab that shows 11s serial number
4 Power-control button and power-on LED
5 Identify LED
6 Node status LED
7 Node fault LED
8 Battery status LED
9 Operator-information panel
10 Front USB ports 1-3
11 Right side latch (releases chassis to slide out on
rails)
12 Drive slot fillers (no empty slots permitted)
13 Boot drives
14 Battery fault LED
15 Batteries
16 Left side latch (releases chassis to slide out on
rails)
17 Machine type and model (MTM) and serial
number
Figure 2. SAN Volume Controller 2145-SV1operator-information panel
1 Power-control button and power-on LED
2 Identify LED
3 Node status LED
4 Node fault LED
5 Battery status LED
Verify that the node boots without error.
The Node status LED should slowly flash and the Node fault LED should be off. If the
node fault LED is lit, see the "Troubleshooting" section of the documentation. When the
battery charge is low, the battery status LED flashes. When the batteries are fully
charged, the battery status LED is on. The battery fault LEDs should be off.
Results
The installation of the SAN Volume Controller hardware is now complete. No
software installation is required.
What to do next
Continue with the instructions in Installing the SAN Volume Controller 2145-24F
expansion enclosure , followed by Initializing the system.