Replacing a Storwize V7000 Gen2 compression-accelerator
Use this procedure to replace a faulty compression-accelerator with a new one received from customer replaceable unit (CRU) or field replaceable unit (FRU) stock.
Procedure
- Complete Procedure: Removing a node canister to remove the faulty compression-accelerator.
- Follow the Procedure: Removing and replacing the lid of a Storwize V7000 Gen2 node canister to remove the lid.
- Locate the faulty compression-accelerator in slot 1. Slot 1 is next to the two host interface adapters in slot 2 and slot 3.
- Gently pull the faulty compression-accelerator upwards to disconnect it and then carefully remove it from the canister.
- Remove the replacement compression-accelerator from its package.
- Set the connecting edge of the replacement compression-accelerator on the connector so that the connectors are aligned.
- Ensure that the compression-accelerator is perpendicular to the canister main board. Align the small tab on the top of the bracket with the alignment hole in the top edge of the slot.
- Maintain alignment while you apply pressure to the top edge of the compression-accelerator opposite the connecting edge to push the compression-accelerator into the connector.
- Check that the compression-accelerator is installed squarely in its slot. If the small tab of the mounting bracket is not positioned correctly, repeat steps 6 onwards to install the compression-accelerator correctly.
- Replace the canister lid, as described in Procedure: Removing and replacing the lid of a Storwize V7000 Gen2 node canister.
- Reinstall the canister in the enclosure from which it was removed in step 1 following the Replacing a Storwize V7000 Gen2 node canister procedure.
- Reconnect the cables to the canister and ensure that the cables go into the same ports from which they were removed in step 1.
- When the canister is back online, check the event log for any new events that relate to hardware changes.