Replacing a Storwize V7000 Gen2host interface adapter
To replace a faulty host interface adapter in a Storwize® V7000 2076-524 with a new one received
from customer replaceable unit (CRU) or field replaceable unit (FRU) stock, use this
procedure.
Important: For correct operation, use the correct SFP
transceivers with each adapter card. The topic Storwize V7000 2076-524 Gen2 replaceable
units identifies the suitable IBM parts.
Use only 8G bps SFP transceivers in the 8 Gbps Fibre Channel adapter cards.
Use only 16 Gbps SFP transceivers in the 16 Gbps Fibre Channel adapter cards.
Use only 10 Gbps SFP transceivers in the 10 Gbps Ethernet (FCoE/iSCSI) adapter card.
Procedure
Complete the following steps to replace a host interface adapter.
Gently pull the host interface adapter upward to
disconnect it 2 , and then carefully remove it from the canister
1 .
Figure 1 displays
removing the host interface adapter.Figure 1. Removing the host interface adapter
Remove the replacement host interface adapter 1 from its package.
Figure 2 displays
installing the host interface adapter.
Set the connecting edge of the replacement host interface adapter 3 on the host interface adapter connector so that
the connectors are aligned.
Ensure that the adapter is perpendicular to the canister main board so that the small tab
on the top of the bracket 2 is aligned with the alignment hole in
the top edge of the slot.
Maintain alignment while applying pressure to the top edge of the host interface adapter opposite the
connecting edge to push the host interface adapter into the connector
4 and 5 .
Figure 2. Installing the host interface adapter
Check that the host interface adapter is installed
squarely in its slot. If the small tab of the mounting bracket is not positioned correctly,
repeat steps 5 onward to install the adapter
correctly.