lsservicestatus
Use the lsservicestatus command to display the status of a node.
Syntax
Parameters
- panel_name
- (Optional) If a panel_name is not provided, the service recommendation for the local node is returned. If a panel_name from the list that is returned by lsservicenodes is specified, then the service recommendation for that node is returned. The command fails if the panel_name ID is not in the list that is returned by lsservicenodes. This output is returned as the node status on all Universal Serial Bus (USB) flash drive commands.
Description
Use this command to display the status of a node. This command provides all the information that can be obtained by using the front panel of a system node.
Nodes that are in the
online_spare state are displayed as active nodes. No
spare node extra fields are left blank.
You can run this command on any node (even one that is not part of a system) to obtain the vital product data (VPD) and error status.
This table shows the possible outputs.
| Attribute | Value |
|---|---|
| panel_name | Indicates the front panel name, enclosure IDs, or canister IDs that identify the node. |
| console_ip | Indicates an Internet Protocol (IP) Version
4 or 6 address. Note: This field might be blank if the node is
not present in a system.
|
| has_nas_key | Indicates the has_nas_key
field value. The values are yes or
no.Note: This field might be blank if the
node is not present in a system.
|
| cluster_id | Indicates the ID of a clustered system. |
| cluster_name | Indicates the name of a system. When you use this parameter, the detailed view of the specific system is displayed and any value that you specified by the -filtervalue parameter is ignored. If you do not specify the cluster_name parameter, the concise view of all systems that match the filtering requirements that are specified by the -filtervalue parameter are displayed. |
| cluster_status | Indicates that the error code is the same as the one displayed on the front panel. |
| cluster_ip_count | Indicates the maximum number of management addresses you can configure. |
| cluster_ip_port | Indicates the system IP port. This field is repeated for each management address. |
| cluster_ip | Indicates the Internet Protocol Version 4 (IPv4) management IP address. This field is repeated for each management address. |
| cluster_gw | Indicates the IPv4 management IP gateway. This field is repeated for each management address. |
| cluster_mask | Indicates the IPv4 management IP mask. This field is repeated for each management address. |
| cluster_ip_6 | Indicates the Internet Protocol Version 6 (IPv6) management IP address. This field is repeated for each management address. |
| cluster_gw_6 | Indicates the IPv6 management IP gateway. This field is repeated for each management address. |
| cluster_prefix_6 | Indicates the IPv6 management IP prefix. This field is repeated for each management address. |
| node_id | Indicates the ID of the node that is being configured. The value is a number. |
| node_name | Indicates the name of the node that is being configured. |
| node_status | Indicates the node status. The values are:
|
| config_node | Indicates whether it is a configuration
node. The values are yes or
no. |
| hardware | Indicates the hardware type. |
| service_IP_address | Indicates the IPv4 service address for the node. |
| service_gateway | Indicates the IPv4 service gateway for the node. |
| service_subnet_mask | Indicates the IPv4 service mask for the node. |
| service_IP_address_6 | Indicates the IPv6 service address for the node. |
| service_gateway_6 | Indicates the IPv6 service gateway for the node. |
| service_prefix_6 | Indicates the IPv6 service prefix for the node. |
| node_IP_address | Indicates the IPv4 management node IP address, which the system uses for node discovery and IP clustering. |
| node_gateway | Indicates the IPv4 management node IP gateway. |
| node_subnet_mask | Indicates the IPv4 management node IP mask. |
| node_code_version | Indicates the version of system code for the node. |
| node_code_build | Indicates the build string for code on the node. |
| cluster_sw_build | Indicates the CSM build that the system is running. |
| node_error_count | Indicates the number of node errors. |
| node_error_data | Indicates the type of node errors. |
| FC_port_count | Indicates the number of FC ports. This field is repeated for each management address. |
| FC_port_id | Indicates the port ID. This field is repeated for each management address. |
| port_status | Indicates the port status. This value must match the port on the front panel, enclosure, or canister. |
| port_speed | Indicates the port speed. This value must match the port speed on the front panel, enclosure, or canister. |
| port_WWPN | Indicates the worldwide port number of the port. |
| SFP_type | Indicates the SFP type. The values are
long-wave or
short-wave. |
| ethernet_port_count | Indicates the number of detected Ethernet ports. |
| ethernet_port_id | Indicates the ID of an Ethernet port. |
| port_status | Indicates the port status. The values are:
|
| port_speed | Indicates the port speed. The values are:
|
| MAC | Indicates a single MAC address. |
| vnport_count | Indicates the number of VN ports that are created on top of each physical Fibre Channel over Ethernet (FCoE) port. |
| vnport_id | Indicates the VN port ID. |
| vnport_wwpn | Indicates the WWPN assigned to the VN port. |
| vnport_FCF_mac | Indicates the MAC address for the FCF to which the VN port is connected. |
| vnport_vlanid | Indicates the VLAN ID used by the VN port. The value is blank for FC ports. |
| product_mtm | Indicates the machine type and model. |
| product_serial | Indicates the node serial number. |
| disk_WWNN_prefix | The most recently used WWNN prefix. |
| node_WWNN | Indicates the last active WWNN stored in the node; blank if no system data. |
| enclosure_WWNN_1 | Indicates the first canister WWNN from the enclosure VPD. |
| enclosure_WWNN_2 | Indicates the second canister WWNN from the enclosure VPD. |
| node_part_identity | Indicates the 11S string from the hardware VPD. |
| node_FRU_part | Indicates the node field-replaceable unit (FRU) part number, if stored in node VPD |
| enclosure_part_identity | Indicates the S11 data. |
| PSU_count | N/A |
| PSU_id | N/A |
| PSU_status | N/A |
| time_to_charge | Indicates the estimated time (in minutes) needed for 50% of the battery to be charged. |
| Battery_charging | Indicates the percentage of charge of the batteries. |
| Battery_count | Indicates the number of expected batteries (two). |
| Battery_id | Indicates the ID of the slot the battery is in. |
| Battery_status | Indicates that the status is
missing, failed,
charging, or active. |
| Battery_FRU_part | Indicates the FRU part number of the battery. |
| Battery_part_identity | Indicates the 11S FRU identity of the battery (includes the serial number). |
| Battery_fault_led | Indicates thee fault light-emitting diode (LED) status. |
| Battery_charging_status | Indicates the battery charge status. |
| Battery_cycle_count | Indicates the number of charge or discharge cycles that are performed by the battery. |
| Battery_powered_on_hours | Indicates the number of hours the battery is in a powered node. |
| Battery_last_recondition | Indicates the system time stamp of the last successful gas gauge calibration. |
| Battery_midplane_FRU_part | Indicates the FRU part number of the battery midplane |
| Battery_midplane_part_identity | Indicates the 11S FRU identity of the battery midplane (which includes the serial number). |
| Battery_midplane_FW_version | Indicates the firmware version that is running on the battery midplane. |
| Battery_power_cable_FRU_part | Indicates the FRU part number of the battery power cable. |
| Battery_power_sense_cable_FRU_part | Indicates the FRU part number of the battery midplane power sense cable. |
| Battery_comms_cable_FRU_part | Indicates the FRU part number of the battery midplane communication cable. |
| Battery_EPOW_cable_FRU_part | Indicates the FRU part number of the battery midplane EPOW cable. |
| local_fc_port_mask | Indicates the FC I/O ports that a system can use for node-to-node communications on a local system if those FC I/O ports exist on a node. The value is 64 binary bits. |
| partner_fc_port_mask | Indicates the FC I/O ports that a system can use for system-to-system communications on a partnered system if those FC I/O ports exist on a node. The value is 64 binary bits. |
| cluster_topology | Indicates the system topology (set by using the chsystem command). |
| site_id | Indicates the site node value. |
| site_name | Indicates the site name. |
| identify_LED | Indicates that the node or node canister
identify LED state (on, off,
or blank). |
| password_reset_enabled | Indicates whether the superuser password
reset is enabled (yes or
no). |
An invocation example
sainfo lsservicestatus
The resulting output:
panel_name 78FNMT0
cluster_id 000002033661160c
cluster_name ron
cluster_status Active
cluster_ip_count 2
cluster_port 1
cluster_ip 9.199.142.183
cluster_gw 9.199.142.1
cluster_mask 255.255.255.0
cluster_ip_6
cluster_gw_6
cluster_prefix_6
cluster_port 2
cluster_ip
cluster_gw
cluster_mask
cluster_ip_6
cluster_gw_6
cluster_prefix_6
node_id 56
node_name node1
node_status Active
config_node Yes
hardware SV1
service_IP_address 9.199.142.181
service_gateway 9.199.142.1
service_subnet_mask 255.255.255.0
service_IP_address_6
service_gateway_6
service_prefix_6
node_code_version 8.2.1.0
node_code_build 147.8.1810261134000
cluster_code_build 147.8.1810261134000
node_error_count 1
error_code 776
error_data 2
fc_ports 4
port_id 1
port_status Not Installed
port_speed N/A
port_WWPN 500507680c318b06
SFP_type Short-wave
port_id 2
port_status Not Installed
port_speed N/A
port_WWPN 500507680c328b06
SFP_type Short-wave
port_id 3
port_status Not Installed
port_speed N/A
port_WWPN 500507680c338b06
SFP_type Short-wave
port_id 4
port_status Not Installed
port_speed N/A
port_WWPN 500507680c348b06
SFP_type Short-wave
ethernet_ports 9
ethernet_port_id 1
port_status Link Online
port_speed 1Gb/s - Full
MAC 98:be:94:6d:21:db
node_IP_address
node_gateway
node_subnet_mask
rdma_type
ethernet_port_id 2
port_status Not Configured
port_speed
MAC 98:be:94:6d:21:da
node_IP_address
node_gateway
node_subnet_mask
rdma_type
ethernet_port_id 3
port_status Not Configured
port_speed
MAC 98:be:94:6d:21:d9
node_IP_address
node_gateway
node_subnet_mask
rdma_type
ethernet_port_id 4
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3d:7c:38
node_IP_address
node_gateway
node_subnet_mask
rdma_type iWARP
ethernet_port_id 5
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3d:7c:30
node_IP_address
node_gateway
node_subnet_mask
rdma_type iWARP
ethernet_port_id 6
port_status Not Configured
port_speed 25Gb/s - Full
MAC 00:07:43:3a:c1:d8
node_IP_address
node_gateway
node_subnet_mask
rdma_type iWARP
ethernet_port_id 7
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3a:c1:d0
node_IP_address 10.10.70.11
node_gateway 10.10.70.1
node_subnet_mask 255.255.255.0
rdma_type iWARP
ethernet_port_id 8
port_status Link Online
port_speed 25Gb/s - Full
MAC ec:0d:9a:30:a2:3f
node_IP_address 192.168.48.54
node_gateway 192.168.48.1
node_subnet_mask 255.255.255.0
rdma_type RoCE
ethernet_port_id 9
port_status Link Online
port_speed 25Gb/s - Full
MAC ec:0d:9a:30:a2:3e
node_IP_address 10.10.90.11
node_gateway 10.10.90.1
node_subnet_mask 255.255.255.0
rdma_type RoCE
product_mtm 2145-SV1
product_serial 78FNMT0
time_to_charge 0
battery_charging 100
dump_name 78FNMT0
node_WWNN 500507680c008b06
disk_WWNN_suffix
panel_WWNN_suffix
UPS_serial_number
UPS_status
enclosure_WWNN_1
enclosure_WWNN_2
node_part_identity
node_FRU_part
enclosure_identity
PSU_count 0
PSU_id 1
PSU_status
PSU_id 2
PSU_status
Battery_count 2
Battery_id 1
Battery_status active
Battery_FRU_part 01LJ604
Battery_part_identity 11S01LJ603YM10BG6BN16B
Battery_fault_led off
Battery_charging_status idle
Battery_cycle_count 16
Battery_power_on_hours 8985
Battery_last_recondition 180828014056
Battery_id 2
Battery_status active
Battery_FRU_part 01LJ604
Battery_part_identity 11S01LJ603YM10BG6BN0VT
Battery_fault_led off
Battery_charging_status idle
Battery_cycle_count 33
Battery_power_on_hours 8985
Battery_last_recondition 180822165529
node_location_copy 1
node_product_mtm_copy 2145-SV1
node_product_serial_copy 78FNMT0
node_WWNN_1_copy 500507680c008b06
node_WWNN_2_copy
latest_cluster_id 0
next_cluster_id 2033681160c
console_IP 9.199.142.183:443
has_nas_key no
fc_io_ports 12
fc_io_port_id 1
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 2
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 3
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 4
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 5
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 6
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 7
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 8
fc_io_port_WWPN
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC
fc_io_port_vlanid
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 9
fc_io_port_WWPN 500507680c318b06
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 1
fc_io_port_id 10
fc_io_port_WWPN 500507680c328b06
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 2
fc_io_port_id 11
fc_io_port_WWPN 500507680c338b06
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 3
fc_io_port_id 12
fc_io_port_WWPN 500507680c348b06
fc_io_port_switch_WWPN
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 4
service_IP_mode static
service_IP_mode_6
machine_part_number
node_machine_part_number_copy
local_fc_port_mask 1111111111111111111111111111111111111111111111111111111111111111
partner_fc_port_mask 1111111111111111111111111111111111111111111111111111111111111111
topology stretched
site_id 1
site_name site1
password_reset_enabled yes
identify_LED off
Battery_midplane_FRU_part 01LJ163
Battery_midplane_part_identity 11S01LJ164YM10BG72R04F
Battery_midplane_FW_version 8.0
Battery_power_cable_FRU_part 01EJ362
Battery_power_sense_cable_FRU_part 01EJ363
Battery_comms_cable_FRU_part 01EJ364
Battery_EPOW_cable_FRU_part
product_name IBM SAN Volume Controller
techport permanent
fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-23,44-24,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54