lsservicestatus

Use the lsservicestatus command to display the status of a node.

Syntax

Read syntax diagramSkip visual syntax diagram sainfo lsservicestatus panel_name

Parameters

panel_name
(Optional) If a panel_name is not provided, the service recommendation for the local node is returned. If a panel_name from the list that is returned by lsservicenodes is specified, then the service recommendation for that node is returned. The command fails if the panel_name ID is not in the list that is returned by lsservicenodes. This output is returned as the node status on all Universal Serial Bus (USB) flash drive commands.

Description

Use this command to display the status of a node. This command provides all the information that can be obtained by using the front panel of a system node.

Nodes that are in the online_spare state are displayed as active nodes. No spare node extra fields are left blank.

You can run this command on any node (even one that is not part of a system) to obtain the vital product data (VPD) and error status.

This table shows the possible outputs.

Table 1. lsservicestatus output
Attribute Value
panel_name Indicates the front panel name, enclosure IDs, or canister IDs that identify the node.
console_ip Indicates an Internet Protocol (IP) Version 4 or 6 address.
Note: This field might be blank if the node is not present in a system.
has_nas_key Indicates the has_nas_key field value. The values are yes or no.
Note: This field might be blank if the node is not present in a system.
cluster_id Indicates the ID of a clustered system.
cluster_name Indicates the name of a system. When you use this parameter, the detailed view of the specific system is displayed and any value that you specified by the -filtervalue parameter is ignored. If you do not specify the cluster_name parameter, the concise view of all systems that match the filtering requirements that are specified by the -filtervalue parameter are displayed.
cluster_status Indicates that the error code is the same as the one displayed on the front panel.
cluster_ip_count Indicates the maximum number of management addresses you can configure.
cluster_ip_port Indicates the system IP port. This field is repeated for each management address.
cluster_ip Indicates the Internet Protocol Version 4 (IPv4) management IP address. This field is repeated for each management address.
cluster_gw Indicates the IPv4 management IP gateway. This field is repeated for each management address.
cluster_mask Indicates the IPv4 management IP mask. This field is repeated for each management address.
cluster_ip_6 Indicates the Internet Protocol Version 6 (IPv6) management IP address. This field is repeated for each management address.
cluster_gw_6 Indicates the IPv6 management IP gateway. This field is repeated for each management address.
cluster_prefix_6 Indicates the IPv6 management IP prefix. This field is repeated for each management address.
node_id Indicates the ID of the node that is being configured. The value is a number.
node_name Indicates the name of the node that is being configured.
node_status Indicates the node status. The values are:
  • active indicates that the node is part of a system and can perform I/O.
  • service indicates that the node is in service mode, standby mode, or node rescue mode.
  • candidate indicates that the node is not part of a system.
  • starting indicates that the node is part of a system and is attempting to join the system.
  • spare indicates that the node is a spare node.
config_node Indicates whether it is a configuration node. The values are yes or no.
hardware Indicates the hardware type.
service_IP_address Indicates the IPv4 service address for the node.
service_gateway Indicates the IPv4 service gateway for the node.
service_subnet_mask Indicates the IPv4 service mask for the node.
service_IP_address_6 Indicates the IPv6 service address for the node.
service_gateway_6 Indicates the IPv6 service gateway for the node.
service_prefix_6 Indicates the IPv6 service prefix for the node.
node_IP_address Indicates the IPv4 management node IP address, which the system uses for node discovery and IP clustering.
node_gateway Indicates the IPv4 management node IP gateway.
node_subnet_mask Indicates the IPv4 management node IP mask.
node_code_version Indicates the version of system code for the node.
node_code_build Indicates the build string for code on the node.
cluster_sw_build Indicates the CSM build that the system is running.
node_error_count Indicates the number of node errors.
node_error_data Indicates the type of node errors.
FC_port_count Indicates the number of FC ports. This field is repeated for each management address.
FC_port_id Indicates the port ID. This field is repeated for each management address.
port_status Indicates the port status. This value must match the port on the front panel, enclosure, or canister.
port_speed Indicates the port speed. This value must match the port speed on the front panel, enclosure, or canister.
port_WWPN Indicates the worldwide port number of the port.
SFP_type Indicates the SFP type. The values are long-wave or short-wave.
ethernet_port_count Indicates the number of detected Ethernet ports.
ethernet_port_id Indicates the ID of an Ethernet port.
port_status Indicates the port status. The values are:
  • online
  • offline
  • not configured
online | offline | not configured
port_speed Indicates the port speed. The values are:
  • 10 Mbps
  • 100 Mbps
  • 1 Gbps
  • 10 Gbps
  • 25 Gbps
  • full
  • half
MAC Indicates a single MAC address.
vnport_count Indicates the number of VN ports that are created on top of each physical Fibre Channel over Ethernet (FCoE) port.
vnport_id Indicates the VN port ID.
vnport_wwpn Indicates the WWPN assigned to the VN port.
vnport_FCF_mac Indicates the MAC address for the FCF to which the VN port is connected.
vnport_vlanid Indicates the VLAN ID used by the VN port. The value is blank for FC ports.
product_mtm Indicates the machine type and model.
product_serial Indicates the node serial number.
disk_WWNN_prefix The most recently used WWNN prefix.
node_WWNN Indicates the last active WWNN stored in the node; blank if no system data.
enclosure_WWNN_1 Indicates the first canister WWNN from the enclosure VPD.
enclosure_WWNN_2 Indicates the second canister WWNN from the enclosure VPD.
node_part_identity Indicates the 11S string from the hardware VPD.
node_FRU_part Indicates the node field-replaceable unit (FRU) part number, if stored in node VPD
enclosure_part_identity Indicates the S11 data.
PSU_count N/A
PSU_id N/A
PSU_status N/A
time_to_charge Indicates the estimated time (in minutes) needed for 50% of the battery to be charged.
Battery_charging Indicates the percentage of charge of the batteries.
Battery_count Indicates the number of expected batteries (two).
Battery_id Indicates the ID of the slot the battery is in.
Battery_status Indicates that the status is missing, failed, charging, or active.
Battery_FRU_part Indicates the FRU part number of the battery.
Battery_part_identity Indicates the 11S FRU identity of the battery (includes the serial number).
Battery_fault_led Indicates thee fault light-emitting diode (LED) status.
Battery_charging_status Indicates the battery charge status.
Battery_cycle_count Indicates the number of charge or discharge cycles that are performed by the battery.
Battery_powered_on_hours Indicates the number of hours the battery is in a powered node.
Battery_last_recondition Indicates the system time stamp of the last successful gas gauge calibration.
Battery_midplane_FRU_part Indicates the FRU part number of the battery midplane
Battery_midplane_part_identity Indicates the 11S FRU identity of the battery midplane (which includes the serial number).
Battery_midplane_FW_version Indicates the firmware version that is running on the battery midplane.
Battery_power_cable_FRU_part Indicates the FRU part number of the battery power cable.
Battery_power_sense_cable_FRU_part Indicates the FRU part number of the battery midplane power sense cable.
Battery_comms_cable_FRU_part Indicates the FRU part number of the battery midplane communication cable.
Battery_EPOW_cable_FRU_part Indicates the FRU part number of the battery midplane EPOW cable.
local_fc_port_mask Indicates the FC I/O ports that a system can use for node-to-node communications on a local system if those FC I/O ports exist on a node. The value is 64 binary bits.
partner_fc_port_mask Indicates the FC I/O ports that a system can use for system-to-system communications on a partnered system if those FC I/O ports exist on a node. The value is 64 binary bits.
cluster_topology Indicates the system topology (set by using the chsystem command).
site_id Indicates the site node value.
site_name Indicates the site name.
identify_LED Indicates that the node or node canister identify LED state (on, off, or blank).
password_reset_enabled Indicates whether the superuser password reset is enabled (yes or no).

An invocation example


sainfo lsservicestatus

The resulting output:


panel_name 78FNMT0
cluster_id 000002033661160c
cluster_name ron
cluster_status Active
cluster_ip_count 2
cluster_port 1
cluster_ip 9.199.142.183
cluster_gw 9.199.142.1
cluster_mask 255.255.255.0
cluster_ip_6 
cluster_gw_6 
cluster_prefix_6 
cluster_port 2
cluster_ip 
cluster_gw 
cluster_mask 
cluster_ip_6 
cluster_gw_6 
cluster_prefix_6 
node_id 56
node_name node1
node_status Active
config_node Yes
hardware SV1
service_IP_address 9.199.142.181
service_gateway 9.199.142.1
service_subnet_mask 255.255.255.0
service_IP_address_6 
service_gateway_6 
service_prefix_6 
node_code_version 8.2.1.0
node_code_build 147.8.1810261134000
cluster_code_build 147.8.1810261134000
node_error_count 1
error_code 776
error_data 2
fc_ports 4
port_id 1
port_status Not Installed
port_speed N/A
port_WWPN 500507680c318b06
SFP_type Short-wave
port_id 2
port_status Not Installed
port_speed N/A
port_WWPN 500507680c328b06
SFP_type Short-wave
port_id 3
port_status Not Installed
port_speed N/A
port_WWPN 500507680c338b06
SFP_type Short-wave
port_id 4
port_status Not Installed
port_speed N/A
port_WWPN 500507680c348b06
SFP_type Short-wave
ethernet_ports 9
ethernet_port_id 1
port_status Link Online
port_speed 1Gb/s - Full
MAC 98:be:94:6d:21:db
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type 
ethernet_port_id 2
port_status Not Configured
port_speed 
MAC 98:be:94:6d:21:da
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type 
ethernet_port_id 3
port_status Not Configured
port_speed 
MAC 98:be:94:6d:21:d9
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type 
ethernet_port_id 4
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3d:7c:38
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type iWARP
ethernet_port_id 5
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3d:7c:30
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type iWARP
ethernet_port_id 6
port_status Not Configured
port_speed 25Gb/s - Full
MAC 00:07:43:3a:c1:d8
node_IP_address 
node_gateway 
node_subnet_mask 
rdma_type iWARP
ethernet_port_id 7
port_status Link Online
port_speed 25Gb/s - Full
MAC 00:07:43:3a:c1:d0
node_IP_address 10.10.70.11
node_gateway 10.10.70.1
node_subnet_mask 255.255.255.0
rdma_type iWARP
ethernet_port_id 8
port_status Link Online
port_speed 25Gb/s - Full
MAC ec:0d:9a:30:a2:3f
node_IP_address 192.168.48.54
node_gateway 192.168.48.1
node_subnet_mask 255.255.255.0
rdma_type RoCE
ethernet_port_id 9
port_status Link Online
port_speed 25Gb/s - Full
MAC ec:0d:9a:30:a2:3e
node_IP_address 10.10.90.11
node_gateway 10.10.90.1
node_subnet_mask 255.255.255.0
rdma_type RoCE
product_mtm 2145-SV1
product_serial 78FNMT0
time_to_charge 0
battery_charging 100
dump_name 78FNMT0
node_WWNN 500507680c008b06
disk_WWNN_suffix 
panel_WWNN_suffix 
UPS_serial_number 
UPS_status 
enclosure_WWNN_1 
enclosure_WWNN_2 
node_part_identity 
node_FRU_part 
enclosure_identity 
PSU_count 0
PSU_id 1
PSU_status 
PSU_id 2
PSU_status 
Battery_count 2
Battery_id 1
Battery_status active
Battery_FRU_part 01LJ604
Battery_part_identity 11S01LJ603YM10BG6BN16B
Battery_fault_led off
Battery_charging_status idle
Battery_cycle_count 16
Battery_power_on_hours 8985
Battery_last_recondition 180828014056
Battery_id 2
Battery_status active
Battery_FRU_part 01LJ604
Battery_part_identity 11S01LJ603YM10BG6BN0VT
Battery_fault_led off
Battery_charging_status idle
Battery_cycle_count 33
Battery_power_on_hours 8985
Battery_last_recondition 180822165529
node_location_copy 1
node_product_mtm_copy 2145-SV1
node_product_serial_copy 78FNMT0
node_WWNN_1_copy 500507680c008b06
node_WWNN_2_copy 
latest_cluster_id 0
next_cluster_id 2033681160c
console_IP 9.199.142.183:443
has_nas_key no
fc_io_ports 12
fc_io_port_id 1
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 2
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 3
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 4
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 5
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 6
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 7
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 8
fc_io_port_WWPN 
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC 
fc_io_port_vlanid 
fc_io_port_type FC
fc_io_port_type_port_id 0
fc_io_port_id 9
fc_io_port_WWPN 500507680c318b06
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 1
fc_io_port_id 10
fc_io_port_WWPN 500507680c328b06
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 2
fc_io_port_id 11
fc_io_port_WWPN 500507680c338b06
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 3
fc_io_port_id 12
fc_io_port_WWPN 500507680c348b06
fc_io_port_switch_WWPN 
fc_io_port_state Inactive
fc_io_port_FCF_MAC N/A
fc_io_port_vlanid N/A
fc_io_port_type FC
fc_io_port_type_port_id 4
service_IP_mode static
service_IP_mode_6 
machine_part_number 
node_machine_part_number_copy 
local_fc_port_mask 1111111111111111111111111111111111111111111111111111111111111111
partner_fc_port_mask 1111111111111111111111111111111111111111111111111111111111111111
topology stretched
site_id 1
site_name site1
password_reset_enabled yes
identify_LED off
Battery_midplane_FRU_part 01LJ163
Battery_midplane_part_identity 11S01LJ164YM10BG72R04F
Battery_midplane_FW_version 8.0
Battery_power_cable_FRU_part 01EJ362
Battery_power_sense_cable_FRU_part 01EJ363
Battery_comms_cable_FRU_part 01EJ364
Battery_EPOW_cable_FRU_part 
product_name IBM SAN Volume Controller
techport permanent
fcportmap 31-11,32-12,33-13,34-14,41-21,42-22,43-23,44-24,61-31,62-32,63-33,64-34,71-51,72-52,73-53,74-54