Known issues
This section details the known issues in version 3.5.0 of IBM® Spectrum Connect and its solution components, along with possible solutions or workarounds (if available).
- HIPER – High Impact Pervasive. A critical issue that IBM has either fixed or plans to fix promptly. Requires immediate customer attention or code upgrade.
- High Impact – Potentially irrecoverable error that might impact data or access to data in rare cases or specific situations/configurations.
- Moderate – Limited functionality issue and/or performance issue with a noticeable effect.
- Service – Non-disruptive recoverable error that can be resolved through a workaround.
- Low – Low-impact usability-related issue.
|
Important:
|
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| SCB-86 | IBM Spectrum Connect | Moderate | When the XIV® storage
credentials are of an XIV domain administrator (supported by
XIV microcode version 11.5 or later), volume mapping might
return the 'LUN already in use' error message. This occurs if the LUN number is already associated with a volume outside of the XIV domain. Currently there is no solution or workaround for this limitation. |
| SCB-94 | IBM Spectrum Connect | Moderate |
Volumes that were migrated from an XIV storage array (A) to another XIV storage array (B) using Hyper-Scale Mobility (online volume migration) might not be manageable. This specifically occurs if the volumes on the original XIV storage array (A) are deleted from the storage array (A), and then the same volume IDs are reused on that storage array (A). If both XIV systems (A and B) are connected to the same Spectrum Connect and this situation occurs, it prevents the management of these volumes through Spectrum Connect. Currently there is no solution or workaround for this limitation. |
| SCB-368 | IBM Spectrum Connect | Moderate | Spectrum Connect fails to lock out a storage admin user account with
LDAP credentials after an unsuccessful login attempt. Currently there is no solution or workaround for this limitation. |
| SCB-753 | IBM Spectrum Connect | Moderate | Upgrading Spectrum Accelerate via RESful API by a user with
insufficient access level may fail. This incomplete procedure prevents further upgrade attempts,
using RESTful API. To avoid this issue, verify that the user performing the Spectrum Accelerate upgrade has sufficient access level for completing the task. |
| SCB-2222 | IBM Spectrum Connect | Moderate | Failure to resolve a DNS hostname may result in the
rabbitmq process malfunction. To avoid this issue, verify that the Spectrum Connect DNS hostname can be resolved. |
| SCB-4407 | IBM Spectrum Connect | Moderate | Thin-provisioned storage resources on IBM FlashSystem® V9000 storage systems cannot be attached to Spectrum Connect services with enabled space efficiency. Currently there is no solution or workaround for this limitation. |
| SCB-4957 | IBM Spectrum Connect | Moderate | Changing user credentials for the Enabler for Containers interface
does not change the authentication token, until the token is deprecated. Currently there is no solution or workaround for this limitation. |
| SCB-5121 | IBM Spectrum Connect | Moderate | LDAP configuration is excluded from the backup and restore
process. To resolve this issue, reconfigure the LDAP access after the Spectrum Connect is restored. |
| SCB-5330 | IBM Spectrum Connect | Moderate | Snapshots of the volumes that were migrated, using HyperSwap® or Hyper-Scale mobility, might not appear in the
vWC snapshot list. Currently there is no solution or workaround for this limitation. |
| SCB-5915 | IBM Spectrum Connect | Moderate | A storage system that lost its connectivity to a Spectrum Connect
instance, cannot be removed from the web UI. Currently there is no solution or workaround for this limitation. |
| SCB-5927 | IBM Spectrum Connect | Moderate | User-defined credentials are not retained after the backup and
restore procedure. A restored Spectrum Connect installation reverts to the default username and
password, without informing the user. To resolve this issue, change the default user credentials after system restore. |
| SCB-5991 | IBM Spectrum Connect | Moderate | DS8000 storage systems with CKD volume aliases cannot be added to
Spectrum Connect, as these volumes have no storage pools associated with them. Currently there is no solution or workaround for this limitation. |
| SCB-48 | IBM Spectrum Connect | Service | Whenever a directory-based storage admin fails to log in (from the Spectrum Connect side) to
any storage array that is in use, Spectrum Connect immediately locks the storage admin user account
and all storage arrays become inaccessible on the Spectrum Connect side. This is to prevent repeated login attempt failures after which the directory server blocks that user account. In such a case, update the storage admin credentials on the storage array with which the login has failed. Alternatively, you can remove that specific storage array from Spectrum Connect and then reset the credentials. You can find the relevant storage array by checking the events.log log file. For example: |
| SCB-85 | IBM Spectrum Connect | Service | Disconnected storage array disappear from the Spectrum Connect web interface after the
upgrade. To avoid this issue, before performing upgrade, verify that all storage arrays are connected to Spectrum Connect properly. |
| SCB-90 | IBM Spectrum Connect | Service | Spectrum Connect cannot use IPv6 addresses for management connection
to the XIV storage systems. To resolve this issue, use IPv4 addressing, when configuring storage arrays. |
| SCB-165 | IBM Spectrum Connect | Service |
Editing the ldap.ini file manually may cause the Spectrum Connect LDAP integration failure. To avoid this issue, use the sc_ldap CLI command for LDAP configuration. |
| SCB-188 | IBM Spectrum Connect | Service | A long-running RESTful API task, such as phase-in, phase-out, etc,
may not update its current state, if Spectrum Connect service has been restarted during its
operation. Currently there is no solution or workaround for this limitation. |
| SCB-598 | IBM Spectrum Connect | Service | In some cases, the Celery service might hang when it is stopped.
To resolve this issue, terminate the Celery background process by using the Linux® kill -9 command. |
| SCB-1023 | IBM Spectrum Connect | Service | Starting from version 2.2.0, a vCO server must be added manually to
the Spectrum Connect. However, if the Spectrum Connect is upgraded from any previous release to
version 2.2.0 or later, a vCO server is added automatically to the GUI. To resolve this issue, remove the vCO server manually after the upgrade is completed. |
| SCB-1355 | IBM Spectrum Connect | Service | LDAP configuration is reset after Spectrum Connect is upgraded from
version 2.1.1 to version 2.2.0. Currently there is no solution or workaround for this limitation. |
| SCB-1359 | IBM Spectrum Connect | Service | If a software on IBM SAN Volume Controller (SVC), which has been added to Spectrum Connect, is re-installed, the storage system still appears connected, but does not function properly. To avoid this issue, remove SVC from Spectrum Connect after the SVC software is re-installed and connect the storage system to Spectrum Connect again. |
| SCB-1361 | IBM Spectrum Connect | Service | The user catalog on the storage systems that run Spectrum Virtualize is not updated
immediately after storage system credentials are changed via the Spectrum Connect GUI. Currently there is no solution or workaround for this limitation. |
| SCB-2495 | IBM Spectrum Connect | Service | Over-provisioning ratio of an XIV storage resource, attached to a service without capabilities, cannot be changed. To resolve this issue, change the over-provisioning ratio, using the XIV GUI, refresh the storage system in the Spectrum Connect GUI and re-attach the resource to the service. |
| SCB-2517 | IBM Spectrum Connect | Service | The postgresql service does not start if the
/tmp folder does not have o+x access permission. To resolve this issue, configure the required permission for the/tmp folder, using the chmod o+x /tmp command. |
| SCB-2888 | IBM Spectrum Connect | Service | Installation fails when the root user has a default
umask, preventing other users from changing root-created directories. To avoid this issue, use the mkdir /opt/ibm and chmod 755 /opt/ibm commands to create the /opt/ibm folder and set correct permissions. |
| SCB-5126 | IBM Spectrum Connect | Service | After upgrading Spectrum Connect to version 3.3.0, any LDAP user with
the username consisting of capital letters becomes a local user. To resolve this issue, change the local user to an LDAP user after upgrading Spectrum Connect to version 3.3.0. |
| SCB-5837 | IBM Spectrum Connect | Service | Spectrum Connect UI allows selecting deduplication mode of data
reduction, when defining a storage service for Spectrum Accelerate Family products. However, this
mode is supported by Spectrum Virtualize storage systems only. Currently there is no solution or workaround for this limitation. |
| SCB-377 | IBM Spectrum Connect | Low | If the IP address of a storage array changes, the
sc_storage_array CLI command is unable to update the IP address of the storage
array. In such a case, use the Spectrum Connect GUI to edit and update the IP address of the storage array (In the Arrays pane, move the mouse pointer over an array that you want to update, and then click the Edit button). |
| SCB-3660 | IBM Spectrum Connect | Low | On RHEL 7.x, due to the Django framework update, Spectrum Connect
upgrade from version 3.0.3 to version 3.1.0 generates several warning messages about missing files.
Despite the messages, the upgrade completes correctly. Currently there is no solution or workaround for this limitation. |
| SCB-3845 | IBM Spectrum Connect | Low | Used capacity indication for storage services does not take into account the space reserved for snapshots on XIV and Spectrum Accelerate storage systems. As a result, the real free hard capacity is less than displayed in Spectrum Connect. Currently there is no solution or workaround for this limitation. |
| SCB-4124 | IBM Spectrum Connect | Low | Storage resource (pool) capacity for the IBM FlashSystem A9000 and A9000R storage systems is limited to 1 PB. Any attempt to create a storage resource, exceeding 1 PB in size results in error message. Currently there is no solution or workaround for this limitation. |
| SCB-4251 | IBM Spectrum Connect | Low | For Storwize® V7000 Unified
storage arrays, the microcode version number, build number, and system ID number are not consistent
when appearing in Spectrum Connect, vSphere Web Client, and storage system management GUIs.
Different version numbers and system IDs are displayed on each platform. Currently there is no solution or workaround for this limitation. |
| SCB-4252 | IBM Spectrum Connect | Low | The registration of Spectrum Connect as a VASA storage provider on
the vCenter server side might fail if an expired self-signed SSL certificate is present on Spectrum
Connect. To resolve this issue, replace the self-signed certificate as explained in the user guide. |
| SCB-4253 | IBM Spectrum Connect | Low | After an upgrade or reinstallation of Spectrum Connect, some DS8000® or SAN Volume Controller storage system identifiers
might change, causing Spectrum Connect to stop synchronizing with these storage systems. To resolve this issue, use the Spectrum Connect GUI or CLI to remove and then add back these storage systems. |
| SCB-4254 | IBM Spectrum Connect | Low | RESTful API may not display the correct number of storage array IP
interfaces. Currently there is no solution or workaround for this limitation. |
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| SCB-1138 | IBM Storage Provider for VMware VASA | Moderate | A VM cannot be created on a datastore, if a size of thick-provisioned
virtual disk size is bigger than any of the Spectrum Virtualize child pools comprising the
vDisk. To avoid this issue, make sure that at least one of the child pools has sufficient disk space to host the datastore vDisk. |
| SCB-1366 | IBM Storage Provider for VMware VASA | Moderate | Rescanning storage providers on VMware vCenter server results in
rescan error, if two Spectrum Connect instances are registered as storage providers for VASA 1.0 and
VASA 2.0. To avoid this issue, register all Spectrum Connect instances as storage providers for VASA 1.0 or VASA 2.0. |
| SCB-2518 | IBM Storage Provider for VMware VASA | Moderate | After a VM migration from a VVol-based datastore, the datastore may
become inaccessible via vWC. To resolve this issue, cancel registration of Spectrum Connect as a VASA storage provider, and run the registration again. |
| SCB-2531 | IBM Storage Provider for VMware VASA | Moderate | When migrating a VM into a VVol-based datastore, which does not
support space efficiency (thin or thick), the migration fails without a specific error message,
explaining the reason for the failure. To avoid this issue, create a VVol-enabled storage service that supports thick and thin provisioning. Then attach storage resources which will be able to support the correct destination VVol-based destination datastore. |
| SCB-2653 | IBM Storage Provider for VMware VASA | Moderate | Storage system information does not appear on the vCenter server
after registering Spectrum Connect as a storage provider for the first time. To resolve this issue, wait for several minutes after the initial registration attempt, and run the registration again. |
| SCB-3712 | IBM Storage Provider for VMware VASA | Moderate | Stretched capability of storage profile cannot be changed for virtual volumes on IBM SAN Volume Controller storage systems. Currently there is no solution or workaround for this limitation. |
| SCB-215 | IBM Storage Provider for VMware VASA | Service | If spaces are included in the IP interface name (iSCSI) of an XIV storage system, that XIV cannot be
monitored by the IBM Storage Provider for VMware VASA, and
information of that XIV array is not visible to the relevant
vCenter server. To avoid this issue, do not include spaces in the IP interface name of the XIV storage system. |
| SCB-255 | IBM Storage Provider for VMware VASA | Service |
Cloning of a virtual machine from a VVol to another VVol on the same IBM SAN Volume Controller (SVC) fails, when the user chooses to customize the VM hardware during the cloning procedure. Moreover, resizing of the source and target VMs fails, if the SVC background copy is in progress. To avoid this issue, customize the virtual machine hardware only after the VM cloning and SVC background copy process are completed. |
| SCB-523 | IBM Storage Provider for VMware VASA | Service | If a storage system is removed and added to Spectrum Connect after its storage resource was
added to a VVol-enabled service, its previous configuration is not preserved after the addition.
This occurs if Spectrum Connect is not registered as a VASA provider. To avoid this issue, verify that Spectrum Connect is registered as a VASA provider before adding the storage system after its removal. In addition, after the storage system is added, it is recommended to check the vCenter log whether Spectrum Connect was identified as an active VASA provider. |
| SCB-1085 | IBM Storage Provider for VMware VASA | Service | When attempting to resize a virtual disk on a storage system, running
Spectrum Virtualize, while the disk formatting is in progress, vCenter displays the following error
message: 'The disk extend operation failed:The VVol target encountered a vendor specific
error.'. To avoid this issue, resize the virtual disk only after the disk formatting process is finished. |
| SCB-2369 | IBM Storage Provider for VMware VASA | Service | A name of a VM, which is created on a VVol datastore, can have only
ASCII-based characters. Currently there is no solution or workaround for this limitation. |
| SCB-3063 | IBM Storage Provider for VMware VASA | Service | When using RESTful API to map a volume to several hosts, which do not
have a common storage resource (pool), this operation may fail To avoid this issue, verify that all hosts to be mapped, share at least one storage resource on the same storage system. |
| SCB-3351 | IBM Storage Provider for VMware VASA | Service | Resizing a VM based on an IBM SAN Volume Controller stretched cluster can fail, if the two copies of the virtual volume are not synchronized. To avoid this issue, wait for the synchronization to complete on storage system side. You can use the SVC lsvdisksyncprogress command to monitor synchronization progress. |
| SCB-3463 | IBM Storage Provider for VMware VASA | Service | The Edit Settings operation for a VVol-based VM fails, if a storage
resource used by the VM datastore has less free space than the VVol data disk of VM. To avoid this issue, make sure that the storage resource for the VM datastore has sufficient free space to accommodate the VVol data disk. |
| SCB-4147 | IBM Storage Provider for VMware VASA | Service | A storage resource can be added to a storage system, which supports
encryption, for a storage service with enabled encryption, even if the encryption functionality is
disabled on the storage system itself. Currently there is no solution or workaround for this limitation. |
| SCB-5586 | IBM Storage Provider for VMware VASA | Service | In deployments with more than one or two vCenter servers and two
storage providers with different priorities, a suspended and reactivated vCenter server fails to
rescan the providers. As a result, the storage providers remain inactive. To resolve this issue, disconnect the inactive storage providers and connect them again to the vCenter server(s). |
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| SCB-417 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | The tab of the IBM Storage Volume object shows incorrect mapping
information. Hosts that cannot access the datastore are shown as not being mapped to the LUN.
Currently there is no solution or workaround for this limitation. |
| SCB-447 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | When using the storage system management GUI (as opposed to the IBM Storage Enhancements GUI in vSphere Web Client) to map a
single volume to more than one ESXi hosts using different LUN IDs, the volume is not properly
recognized by vSphere Web Client and cannot be managed by the IBM Storage Enhancements. In addition, multiple errors might occur on the vSphere Web Client
during the use or modification of that volume. To avoid this issue, always use the same LUN ID when mapping a volume to multiple ESXi hosts via the storage system management GUI. |
| SCB-3654 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | When a vCenter user without storage management privileges adds a
vCenter interface to Spectrum Connect and then modifies the vCenter with the administrator
credentials, logs into vSphere Web client and performs volume operations, some of these operations
may fail. To resolve this issue, remove the vCenter interface from Spectrum Connect, and add the vCenter again, using valid administrator credentials. |
| SCB-3759 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | After VMware vCenter reboot or upgrade, the changes made for the vCenter before the reboot or upgrade fail to propagate to the IBM extension for vCenter. To resolve this issue, restart the refresh vWC service by logging into the Spectrum Connect host as root and running the /etc/init.d/ibm_spectrum_control restart_vwc_refresh. |
| SCB-4184 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate |
Removing a vCenter interface from Spectrum Connect may cause unstable behavior of the vWC plug-in. To resolve this issue, perform one of the following procedures, depending on the Spectrum Connect
and vCenter deployment scenarios:
|
| SCB-4193 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | When provisioning a new volume using vSphere Web Client, the Max
Provision Size of the new volume is permanently set to 0. This results in volume creation
failure. To avoid this issue, connect all vCenter servers in the SSO to the same Spectrum Connect instance. |
| SCB-5356 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | After upgrade to version 3.4.0, in rare cases, Spectrum Connect might
lose connection with the vWC plug-in. To resolve this issue, restart the web plug-in service on the relevant vCenter server. |
| SCB-5841 | IBM Storage Enhancements for VMware vSphere Web Client | Moderate | A volume cannot be resized via vSphere Web Client. To resolve this issue, resize the volume using the storage system web-based user interface or CLI. |
| SCB-154 | IBM Storage Enhancements for VMware vSphere Web Client | Service | If a vCenter server is disconnected from Spectrum Connect during the
upgrade, the vWC extension appears with the previous version, when the vCenter server is
re-activated. To resolve this issue, remove and reattach the vCenter server on Spectrum Connect. |
| SCB-381 | IBM Storage Enhancements for VMware vSphere Web Client | Service | A vCenter server that receives a new IP address retains information
about storage resources of a Spectrum Connect connected to it prior to the address change. If the
vCenter server is added to another Spectrum Connect instance, the previously connected arrays and
pools remain visible in the vWC. To resolve this issue, log into vCenter Managed Object Browser (MOB) at https://<vCenter_server_IP>/mob., using your vCenter credentials. Navigate to . Enter com.ibm.storage.vwc, when a pop-up window is displayed, and click Invoke Method twice. Repeat registration of the vCenter server on the newly connected Spectrum Connect. |
| SCB-399 | IBM Storage Enhancements for VMware vSphere Web Client | Service | If a volume is deleted, using vSphere Web Client, but the deletion
fails on the storage system, the volume is removed from the vSphere Web Client display. In this
case, the volume is successfully unmapped from the host, but there is no indication on the vSphere
Web Client that the volume still exists. To avoid this issue, delete the volume from the storage system directly. |
| SCB-671 | IBM Storage Enhancements for VMware vSphere Web Client | Service |
vWC volume creation and mapping task may fail, if a source pool that exists on an XIV storage system within a domain, has been attached to service created by the default Spectrum Control user. To avoid this issue, associate the default Spectrum Connect user with the storage array domain. |
| SCB-701 | IBM Storage Enhancements for VMware vSphere Web Client | Service | A volume being moved between two XIV storage systems using IBM Hyper-Scale Mobility,
cannot be unmapped in vWC from the ESXi host after the source storage system enters the proxy
mode. To resolve this issue, remove volume mapping using the XIV GUI. |
| SCB-775 | IBM Storage Enhancements for VMware vSphere Web Client | Service | Creating a volume with minimum size (87 GB) on XIV,
Spectrum Accelerate or FlashSystem A9000/9000R may fail, if the target pool size is
smaller than 103 GB. To avoid this situation, increase the storage pool size to be 103 GB or bigger. |
| SCB-2479 | IBM Storage Enhancements for VMware vSphere Web Client | Service | Creating and mapping a volume on a Spectrum Accelerate Family product
via the vWC plug-in may fail if a storage resource is connected to a host outside of a storage
system domain. To avoid this situation, verify that all the hosts defined on the vCenter are also defined on the storage systems and are associated with the domain. In addition, make sure that the default storage credentials defined in Spectrum Connect belong to the domain as well. |
| SCB-2519 | IBM Storage Enhancements for VMware vSphere Web Client | Service | Creating and mapping a volume on a Spectrum Accelerate Family product
via the vWC plug-in may fail if ESXi LUNs used by the volumes do not belong to any domain, while the
Spectrum Connect storage credentials are associated with a specific domain. To avoid this situation, verify that volumes outside of a domain are not mapped to the target host. |
| SCB-3049 | IBM Storage Enhancements for VMware vSphere Web Client | Service | A connection session between Spectrum Connect and vCenter server
remains open after Spectrum Connect has been restarted or the vCenter server has been removed and
added again via the Spectrum Connect GUI. This results in multiple concurrent connection sessions
with different IDs between the servers. To resolve this issue, manually remove the redundant session via the vSphere Web Client (). |
| SCB-3456 | IBM Storage Enhancements for VMware vSphere Web Client | Service | Resizing a stretched volume on IBM SAN Volume Controller can fail, if the two copies of the volume are not synchronized. To avoid this issue, wait for the synchronization to complete on storage system side. You can use the SVC lsvdisksyncprogress command to monitor synchronization progress. |
| SCB-3637 | IBM Storage Enhancements for VMware vSphere Web Client | Service | If a volume is mapped to an ESXi 6.5 host, the size of the volume
under the IBM Storage Volumes tab does not change after its extension. To resolve this issue, rescan the host manually. |
| SCB-4525 | IBM Storage Enhancements for VMware vSphere Web Client | Service | Creation of several volumes and their subsequent renaming might fail
in mid-process with an error, indicating insufficient memory. As a result, some of the volumes are
created successfully, and some of them are not. Currently there is no solution or workaround for this limitation. |
| SCB-705 | IBM Storage Enhancements for VMware vSphere Web Client | Low | A volume, whose deletion fails, disappears from the volume list. The
volume reappears in the list after the next population. Currently there is no solution or workaround for this limitation. |
| SCB-836 | IBM Storage Enhancements for VMware vSphere Web Client | Low |
If a combination of both iSCSI and FC initiator port types is defined for an ESXi host, mapping volumes to that ESXi host causes both iSCSI and FC to be used for those volumes. To avoid this situation, use the storage system management tools to define only one active protocol type (iSCSI or FC) for the initiators of each ESXi host. |
| SCB-838 | IBM Storage Enhancements for VMware vSphere Web Client | Low | If a volume is mapped to two or more ESXi hosts that are managed by
more than one vCenter server, volume operations fail. To avoid this issue, do not map a specific volume to ESXi hosts that are not managed by the same vCenter server. |
| SCB-2488 | IBM Storage Enhancements for VMware vSphere Web Client | Low | When provisioning a volume on storage service for XIV storage systems with enabled compression, the provisioning fails, if the volume size is below 51 GB. The generated error message is not sufficiently clear. To avoid this issue, a size of a volume, provisioned on a storage service with enabled compression, must be larger than 51 GB. |
| SCB-2718 | IBM Storage Enhancements for VMware vSphere Web Client | Low | When delegating a single VVol-type service to several vCenter
servers, the service VVols will be exposed to all servers, even though they relate to only one of
them. Currently there is no solution or workaround for this limitation. |
| SCB-2970 | IBM Storage Enhancements for VMware vSphere Web Client | Low | Actions are allowed on volumes that are mapped to a disconnected or
non-responsive ESXi host. The volume actions will fail due to the host status. Moreover, if the
disconnected host is added to another vCenter server, the volume operations will fail on the new
server as well. To avoid this situation, verify that the host is connected to the vCenter server. If a disconnected or non-responsive host is connected to a new server, remove it from the original server to allow proper volume performance. |
| SCB-2974 | IBM Storage Enhancements for VMware vSphere Web Client | Low | When a LUN is shared between several ESXi hosts, its number must be
the same on all hosts. To avoid this situation, verify that the shared LUN number is available for all hosts. |
| SCB-2991 | IBM Storage Enhancements for VMware vSphere Web Client | Low | If a volume is shared between several datacenters, volume-related
objects, such as a datastore or a VM that belong to other datacenters, are missing from the
vWC. Currently there is no solution or workaround for this limitation. |
| SCB-2999 | IBM Storage Enhancements for VMware vSphere Web Client | Low | When a disk is removed from a VM created on a VVol-based datastore,
but not removed from the datastore, the VM is still listed as a related object on the VVol.
Currently there is no solution or workaround for this limitation. |
| SCB-3014 | IBM Storage Enhancements for VMware vSphere Web Client | Low | There is no indication of storage objects that exist on a storage
system outside of a domain available for a user certain storage credentials. As a result, such vWC
actions as creating and mapping a volume fail if a volume with the same name already exists on a
storage system. To avoid this situation, verify that a new volume name is unique on the current storage system. In addition, make sure that ESXi hosts are not mapped to the volumes outside of the user domain. |
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| SCB-140 | IBM Storage Plug-in for VMware vRealize Orchestrator | Moderate | If the Map workflow uses initiators that are
not configured on the storage array, the workflow succeeds even though the initiators are silently
ignored. Currently there is no solution or workaround for this limitation. |
| SCB-141 | IBM Storage Plug-in for VMware vRealize Orchestrator | Low | Due to a known issue in VMware vRealize Orchestrator, title texts are
displayed improperly after clicking the IBM Storage tab. Currently there is no solution or workaround for this limitation. |
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| SCB-796 | IBM Storage Management Pack for VMware vRealize Operations Manager | Moderate | When data collection interval is set to 1 minute, the array IOPS
statistics are presented as 0. Currently there is no solution or workaround for this limitation. |
| SCB-845 | IBM Storage Management Pack for VMware vRealize Operations Manager | Moderate | If the vROps server becomes unreachable while Spectrum Connect is
still reporting to it, the reporting ceases when the vROps server becomes reachable again. To resolve this issue, restart the Spectrum Connect service. |
| SCB-841 | IBM Storage Management Pack for VMware vRealize Operations Manager | Service | The thresholds reported to the vROps server are tailored for XIV microcode version 11.2 or later, but not for earlier XIV microcode versions. To resolve this issue, manually update to the thresholds in vROps to match the XIV microcode that you are using. |
| SCB-842 | IBM Storage Management Pack for VMware vRealize Operations Manager | Service | Duplicate thresholds might appear in vROps if a vROps server was
removed from Spectrum Connect and then re-added. To resolve this issue, delete the duplicate thresholds. |
| SCB-844 | IBM Storage Management Pack for VMware vRealize Operations Manager | Low | If a storage object name contains spaces, it is displayed in the
vROps custom view with underlines instead of spaces. Currently there is no solution or workaround for this limitation. |
| Ticket ID | Component | Severity | Description |
|---|---|---|---|
| UB-66 | IBM Storage Enabler for Containers | Moderate | If a volume is renamed directly on a storage system and removed from a node,
it is deleted from the Enabler for Containers database, but remains intact on the storage itself.
To avoid this issue, do not rename volumes on a storage system, if the volumes are used by containerized applications. |
| UB-380 | IBM Storage Enabler for Containers | Moderate | When creating a PVC with an underscore, _, in pv-name
label, the volume is created on the storage system, but it fails to be created in the Kubernetes
environment. To avoid this issue, do not use an underscore in a PVC pv-name label. |
| UB-454 | IBM Storage Enabler for Containers | Moderate | Identifying incorrect IP address of the Enabler for Containers server
by the FlexVolume driver might take up to 2 minutes. Currently there is no solution or workaround for this limitation. |
| UB-499 | IBM Storage Enabler for Containers | Moderate | On the storage systems that run Spectrum Virtualize, volume
operations might fail, if a Kubernetes node name starts with a number To avoid this issue, do not use numbers as initial symbols in Kubernetes node names. |
| UB-579 | IBM Storage Enabler for Containers | Moderate | A container might remain in the ContainerCreating status
for a long period of time. In addition, an unresponsive sg_inq process exists on a pod
worker node and failed multipath devices are present in the system. To resolve this issue, terminate the unresponsive process, using the -9 signal, or run the multipath -F command to clean the faulty devices, holding the process. |
| UB-612 | IBM Storage Enabler for Containers | Moderate | PVC creation process might remain in the Pending state for more than two minutes. In addition, the following message is stored in the IBM Storage Enabler for Containers pod log No storage resource that can match the requirements found. Reason is: A volume with this
name already exists. Array is: storage_system_name. Requested volume name is: volume_name..
To resolve this issue:
|
| UB-1060 | IBM Storage Enabler for Containers | Moderate | If a pod termination takes more than six minutes, Kubernetes master
node attempts to detach the pod automatically. This results in the pod becoming unresponsive,
persisting in the Terminating status. To resolve this issue, unmount the multipath
device and delete the pod manually, using the following procedure:
|
| UB-1073 | IBM Storage Enabler for Containers | Moderate | Pod becomes unresponsive, persisting in the
ContainerCreating status. An error indicating a failure to discover a new volume WWN,
while running the multipath -ll command, is stored in the FlexVolume log. This
log belongs to the node, where the pod was scheduled. To resolve this issue, restart the multipathd service by running the service multipathd restart command. |
| UB-1103 | IBM Storage Enabler for Containers | Moderate | Installation of the IBM Storage Enabler
for Containers fails on DS8000 storage systems. To resolve this issue, use the following procedure:
|
| UB-1525 | IBM Storage Enabler for Containers | Moderate | Installation of Enabler for Containers on x86 or IBM System Z servers
for Spectrum Virtualize storage systems in Fibre Channel environment might fail. To avoid this issue, create LUN0 on a storage system and map it to all worker nodes before installing IBM Storage Enabler for Containers. |