1089 One or more fans are failing.
Explanation
One or more fans are failing.
For the 2145-DH8, a fan has a fault condition.
User response
- Determine the failing fan(s) from the fan indicator on the system board or from the text of the error data in the log. The reported fan for the 2145-CF8, or 2145-CG8 matches the fan module position. Each fan module contains two fans.
- For the 2145-DH8, mechanically stop fan or remove fan. If a fan is not installed, shut down the node, open it, and install the fan. If a fan is installed, replace fan FRU indicated by the FAN identifier that is supplied in the Extra data.
- Exchange the FRU for a new FRU.
- Go to repair verification MAP.
- Fan number: Fan module position
- 1 or 2 :1
- 3 or 4 :2
- 5 or 6 :3
- 7 or 8 :4
- 9 or 10:5
- 11 or 12:6
Possible Cause-FRUs or other:
- Fan module (100%)