Before you connect the SAN Volume Controller
2145-CF8 to
the SAN, you must connect the Ethernet and Fibre Channel cables.
Before you begin
Before you begin
this task, see the customer's cable-connection table to find out where to connect the Ethernet and
Fibre Channel cables.
One or two Ethernet cables can be connected to the SAN Volume Controller
2145-CF8.
The customer's cable connection table indicates the number of
cables to connect. If only one cable is connected, the cable must
be connected to Ethernet port 1.
About this task
To connect the SAN Volume Controller
2145-CF8 to
the SAN and to the Ethernet network, perform the following steps:
Procedure
- Connect the Ethernet cables
to Ethernet port 1, as shown by 9 in Figure 1 and Ethernet
port 2 ( 8 ).
- Connect the other end of the Ethernet cable to
the proper connector on the Ethernet hub or switch.
Figure 1. Connectors on the rear of the SAN Volume Controller 2145-CG8 or 2145-CF8
- 1 Fibre Channel port 1
- 2 Fibre Channel port 2
- 3 Fibre Channel port 3
- 4 Fibre Channel port 4
- 5 Power cord connector for power supply 1
- 6 Power cord connector for power supply 2
- 7 Serial connection for UPS communication cable
- 8 Ethernet port 2
- 9 Ethernet port 1
Attention: When routing the Fibre Channel cables,
do not tighten the cable straps or bend the cables to a radius smaller than 76 mm (3 in.).
- Connect the
Fibre Channel cables to the Fibre Channel ports as required by the user's
configuration.
- Connect the other ends of the Fibre Channel cables
to the proper connectors of the Fibre Channel
switches.