Port settings for the EMC VMAX
Target port characteristics can be set by using the set port command from the Symmetrix Command-Line Interface (SYMCLI).
The target port characteristics can be viewed by using the symcfg command from the SYMCLI.
Table 1 lists the options that must be used with the system.
| VMAX 10K, 20K, 40K | VMAX3 100K, 200K, 400K (SAN Volume Controller or Storwize® family Version 7.3 or later) | Notes | |
|---|---|---|---|
| Director bit SCSI flags | |||
| Negotiate_Reset(N) | Disabled | Disabled | |
| Soft_Reset(S) | Disabled | Disabled | |
| Environ_Set(E) | Disabled | Disabled | |
| HP3000_Mode(B) | Disabled | Disabled | |
| Common_Serial_Number(C) | Enabled | Enabled | |
| Disable_Q_Reset_on_UA(D) | Disabled | Disabled | |
| Sunapee(SCL) | Disabled | Disabled | |
| Siemens(S) | Disabled | Disabled | |
| Sequent(SEQ) | Disabled | Disabled | |
| Avoid_Reset_Broadcast(ARB) | Disabled | Disabled | |
| Server_On_AS400(A4S) | Disabled | Disabled | |
| SCSI_3(SC3) | Enabled | Enabled |
|
| SPC2_Protocol_Version(SPC2) | Enabled | Enabled |
|
| SCSI_Support1(OS2007) | Enabled | Enabled | This director bit can be modified to comply with the required setting or desired setting if it is optional either on the target port basis or initiator basis. |
| WP_Bypass(WPBP) | Disabled | Disabled | |
| Director bit Fibre Channel flags | |||
| Volume_Set_Addressing(V) | Disabled | Disabled | |
| Non_Participating(NP) | Disable | Disabled | |
| Init_Point_to_Point(PP) | Enabled | Enabled | |
| Access_Logix(ACLX) | Enabled | Enabled | |
| OpenVMS(OVMS) | Disabled | Disabled | |
| AS400(AS4) | Disabled | Disabled | |
| Auto_Negotiate(EAN) | Enabled | Enabled | |
| VNX_Gateway_Direct_Attach | Disabled | Disabled | |
| Show_ACLX_Device | N/A | Disabled | Do not enable this bit for system attachment. |