SAN Volume Controller 2145-SV1 Fibre Channel and Ethernet port numbers

Fibre Channel port numbers for the SAN Volume Controller 2145-SV1 vary, depending on how many host interface adapters are installed, and in which slots. Port numbers also depend on the configuration of the 10Gbps Optical Ethernet adapter.

Figure 1 shows a typical configuration of the SAN Volume Controller 2145-SV1 with the following adapters installed:

Table 1. The PCIe expansion slots in which an adapter can be used
PCIe expansion slot number Adapter
1 Not used
2 12 Gbps SAS adapter
3 16 Gbps Fibre Channel adapter or 10 Gbps Ethernet adapter*
4 16 Gbps Fibre Channel adapter or 10 Gbps Ethernet adapter
5 Compression Accelerator
6 16 Gbps Fibre Channel adapter or 10 Gbps Ethernet adapter
7 16 Gbps Fibre Channel adapter or 10 Gbps Ethernet adapter
8 Compression Accelerator
* Slots 3, 4, 6, and 7 can contain a 16G FC or a 10G Ethernet adapter, but only one 10 Gbps Ethernet adapter is supported.

The following figure shows the physical Fibre Channel port numbers when the 10 Gbps Optical Ethernet adapter is configured for Fibre Channel over Ethernet (FCoE) communications.

Figure 1. Fibre Channel port numbers in a typical configuration
Physical Fibre Channel port numbers for the SAN Volume Controller 2145-SV1
  •  1  -  16  Fibre Channel ports 1-16

Figure 2 shows the Ethernet port numbers for the SAN Volume Controller 2145-SV1 when the 10 Gbps Optical Ethernet adapter is configured for iSCSI communications.

Figure 2. Ethernet port numbers for iSCSI communication
Ethernet port numbers for the SAN Volume Controller 2145-SV1
  •  1  -  3  10 Gbps Ethernet ports 1-3
  •  4  -  7  10 Gbps optical Ethernet ports 4-7