Installing the support rails for the SAN Volume Controller 2145-CF8
You must install the support rails that hold the SAN Volume Controller 2145-CF8 node.
Before you begin
Figure 1 shows the items that you need to install the SAN Volume Controller 2145-CF8 node in a rack.
Figure 1. SAN Volume Controller
2145-CF8 cable-management arm, support rails, and associated parts

| Reference | Description | Quantity |
|---|---|---|
| 1 | Slide rail (left) | 1 |
| 2 | Slide rail (right) | 1 |
| 3 | M6 screws | 4 |
| 4 | Large cable tie | 1 |
| 5 | Cable ties | 5 |
| 6 | Cable-management support arm | 1 |
| 7 | Cable-management arm assembly | 1 |
Notes:
- With some types of racks, you might find it helpful to remove the rack doors and side panels to provide easier access during installation.
- The slide rails are marked (RIGHT / FRONT and LEFT / FRONT) for proper placement on the rack flanges.
- The front and back of each rail has a spring-loaded rail-locking carrier, which can be locked in the open position and then released when the rail is in the rack.
When you are ready to install the support rails, use the customer's hardware-location chart and the Electronic Industries Alliance (EIA) positions on the rack to determine where in the rack that the SAN Volume Controller node is to be installed.
About this task
To install the support rails, follow these steps: