Optional features
The SAN Volume Controller 2145-SV1 and SAN Volume Controller 2145-DH8 nodes support optional features, which can be installed concurrently.
Features or models
Table 1 lists the optional features and models that can be installed on your SAN Volume Controller 2145-SV1 or SAN Volume Controller 2145-DH8 system. Only an IBM® service support representative (SSR) can remove or install adapters on the system.
| Feature or model | Description | Minimum software level required | Maximum per 2145-DH8 node | Maximum per 2145-SV1 node |
|---|---|---|---|---|
| 2145-92F | SAN Volume Controller expansion enclosure for 92 3.5-inch SAS drive slots | 7.8.0 | 8 | 8 |
| 2145-24F | SAN Volume Controller expansion enclosure, which is required for 2.5-inch SAS drives | 7.3.0 for up to 2 enclosures 7.7.0 for up to 2 enclosures (12F, 24F, or both) 7.7.1 for up to 20 enclosures |
20 | 20 |
| 2145-12F | SAN Volume Controller expansion enclosure, which is required for 3.5-inch SAS drives | 7.3.0 for up to 2 enclosures 7.7.0 for up to 2 enclosures (12F, 24F, or both) 7.7.1 for up to 20 enclosures |
20 | 20 |
| AH10 | 4-port 8 Gbps Fibre Channel adapter with four short-wave
SFP
transceivers Notes:
|
7.3.0 or 7.6.0.3 | 4 | 0 |
| AH11 | 2-port 16 Gbps Fibre Channel adapter with two short-wave SFP
transceivers The maximum fiber length is 10 km when used with feature ACHU and single-mode fiber optic cable |
7.4.0 | 4 | 0 |
| AH12 | 4-port 10 Gbps Ethernet adapter with four SFP transceivers | 7.3.0 | 1 | 1 |
| AH13 | 4-port 12 Gbps SAS adapter. Required for Model 24F attachment | 7.3.0 | 1 | 1 |
| AH14 | 4-port 16 Gbps Fibre Channel adapter with four short-wave SFP
transceivers Note: The maximum fiber length is 5 km when used with feature ACHU and single-mode fiber
optic cable.
|
7.6.0 | 4 | 4 |
| AH1T | Two 8 Gbps Fibre Channel long-wave SFP Transceivers for optional use with feature AH10 | 7.3.0 | N/A | |
| ACHU | Two 16 Gbps Fibre Channel long-wave SFP Transceivers for optional use with feature AH11 or AH14 | 7.3.0 | ||
| AH1A | Compression accelerator. Requires feature AH1B | 7.3.0 | 2 | 2 |
| AH1B | Second microprocessor and 32 GB RAM | 7.3.0 | 1 | 0 (in base) |
| AH20 | 200 GB 12 Gbps SAS 2.5-inch tier 0 flash drive | 7.3.0 | ||
| AH21 | 400 GB 12 Gbps SAS 2.5-inch tier 0 flash drive | 7.3.0 | ||
| AH22 | 800 GB 12 Gbps SAS 2.5-inch tier 0 flash drive | 7.3.0 | ||
| AH23 | 1.6 TB 12 Gbps SAS 2.5-inch tier 0 flash drive | 7.3.0 | ||
| AH24 | 3.2 TB 12 Gbps SAS 2.5-inch tier 0 flash drive | 7.4.0 | ||
| AH30 | 4.0 TB 7.2 K RPM 3.5-inch nearline hard disk drive | 7.7.0 | ||
| AH31 | 6.0 TB 7.2 K RPM 3.5-inch nearline hard disk drive | 7.7.0 | ||
| AH32 | 8.0 TB 7.2 K RPM 3.5-inch nearline hard disk drive | 7.7.0 | ||
| AH33 | 10.0 TB 7.2 K RPM 3.5-inch nearline hard disk drive | 7.8.0 | ||
| AH40 | 300 GB 15 K RPM 2.5-inch hard disk drive | 7.6.1.4 | ||
| AH41 | 600 GB 15 K RPM 2.5-inch hard disk drive | 7.6.1.4 | ||
| AH50 | 900 GB 10 K RPM 2.5-inch hard disk drive | 7.6.1.4 | ||
| AH51 | 1.2 TB 10 K RPM 2.5-inch hard disk drive | 7.6.1.4 | ||
| AH52 | 1.8 TB 10 K RPM 2.5-inch hard disk drive | 7.6.1.4 | ||
| AH60 | 2.0 TB 7.2 K RPM 2.5-inch nearline hard disk drive | 7.6.1.4 | ||
| AH2A | 1.92 TB 2.5-inch SAS tier 1 flash drive | 7.6.1.4 | ||
| AH2B | 3.84 TB 2.5-inch SAS tier 1 flash drive | 7.7.0 | ||
| AH2C | 7.68 TB 2.5-inch SAS tier 1 flash drive | 7.8.0 | ||
| AH2D | 15.3 TB 2.5-inch SAS tier 1 flash drive | 7.8.0 | ||
| AH70 | 600 GB 15 K RPM SAS hard disk drive for 92F | 7.8.0 | ||
| AH73 | 1.2 TB 10 K RPM SAS hard disk drive for 92F | 7.8.0 | ||
| AH74 | 1.8 TB 10 K RPM SAS hard disk drive for 92F | 7.8.0 | ||
| AH77 | 6 TB 7.2 K RPM nearline SAS hard disk drive for 92F | 7.8.0 | ||
| AH78 | 8 TB 7.2 K RPM nearline SAS hard disk drive for 92F | 7.8.0 | ||
| AH79 | 10 TB 7.2 K RPM nearline SAS hard disk drive for 92F | 7.8.0 | ||
| AH7D | 1.6 TB SAS tier 0 flash drive for 92F | 7.8.0 | ||
| AH7E | 3.2 TB SAS tier 0 flash drive for 92F | 7.8.0 | ||
| AH7J | 1.92 TB SAS tier 1 flash drive for 92F | 7.8.0 | ||
| AH7K | 3.84 TB SAS tier 1 flash drive for 92F | 7.8.0 | ||
| AH7L | 7.68 TB SAS tier 1 flash drive for 92F | 7.8.0 | ||
| AH7M | 15.3 TB SAS tier 1 flash drive for 92F | 7.8.0 |
2145-SV1 PCI express expansion slot rules
Table 3 lists the optional adapters that are supported in each PCI express expansion slot.
| PCIe slot | Options that are supported in the specified slot |
|---|---|
| 1 |
|
| 2 |
|
| 3 | |
| 4 | |
| 5 | |
| 6 | |
| 7 | |
| 8 |
|
2145-DH8 PCI express expansion slot rules
Use the rules in Table 3 to see which adapters are supported in each PCI express expansion slot.