Ensure that the planning charts and tables are complete and that you have received all
the required parts as you prepare for the installation of the optional redundant AC-power
switch, the uninterruptible power
supply, and the SAN Volume Controller
2145-CF8.
Before you begin
Note: The parts for installation of the SAN Volume Controller
2145-CF8 are the
same as the parts for the installation of the SAN Volume Controller
2145-CF8. Sections
in this task refer to CG8 parts and documentation but are valid for the CF8.
Figure 1 shows the major
hardware components that you need for installing your
uninterruptible power
supply.
Figure 1. Parts provided for SAN Volume Controller
2145-CF8 hardware installation in a
rack
- 1
SAN Volume Controller node
- 2
SAN Volume Controller support rails (2)
- 3
2145
UPS-1U
- 4
2145
UPS-1U support rails
(2)
- 5 Power cable assembly
- 6
SAN Volume Controller cable-management support arm
- 7
SAN Volume Controller cable-management arm
assembly
- 8 Optionally, one or more redundant AC-power
switches, two mounting brackets
per switch, and power cables
- 9
2145
UPS-1U cable-retention bracket
- 10
SAN Volume Controller cable-retention brackets
- 11
2145
UPS-1U mounting brackets
Not shown in Figure 1 are two 2145
UPS-1U
input-power
cables that are provided. One
cable comes with the 2145
UPS-1U; it has an IEC 320-C14 plug, which is suitable for almost every rack-mounted power distribution unit. The other country-specific cable
comes with the SAN Volume Controller node; this cable is
intended for your country-specific power sockets. Use only one of these cables.
Before you start the installation, verify that all the parts that were ordered have been received
and that all the component assemblies are complete. Verify that you know the quantity of nodes and
optional features that were ordered.
Three boxes are shipped for each node: one box contains the uninterruptible power
supply, one box contains the publications,
and the third box contains all of the other parts. A label on the third, or main, box indicates the
features that were shipped.
Note: - You must install at least two SAN Volume Controller
nodes. Each node requires an uninterruptible power
supply.
- Optionally, install two redundant AC-power
switches to power the nodes in an
I/O group through two 2145 UPS-1U
units.
- You must ensure that you have the appropriate cables to connect the redundant AC-power
switch or the uninterruptible power
supply to the power distribution unit. See Redundant AC-power environment requirements and Power cables for the 2145 UPS-1U
for more details.
About this task
To prepare for
installation:
Procedure
- Ensure that you have everything you need for
installation, including the customer-completed planning tables and charts. The customer can obtain
the planning tables and charts from www.ibm.com/support.
The planning information provides
guidelines for completing the planning tables and charts. These tables include the location of
hardware, cable connection, and configuration data information that you need to complete the
installation procedures. If you are connecting cables to switches that are currently in use, confirm
with the customer that it is safe for you to proceed. Go no further with these instructions until
you are satisfied that all the information is correct and valid.
- The label on the main box indicates features that were shipped. Make sure that the contents and
quantity match the
order.
The following feature codes are included:- Feature code 0010: initial SAN Volume Controller
2145-CF8 software preinstalled on
feature code 3001 and 3002
- One of the following feature codes:
- Feature code 3001: initial SAN Volume Controller
2145-CF8 node, quantity 1
- Feature code 3002: additional SAN Volume Controller
2145-CF8 node, quantity 1
- Optionally, feature code 4500: Flash
drive attachment, quantity 1
- Optionally, feature code 4601: 146 GB Flash
drive, quantity 1 - 4
- One of the following country-specific SAN Volume Controller
2145-CF8 power cable feature codes:
9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724, 9725, 9726, or 9727.
- Feature code 8115: 2145
UPS-1U kit,
quantity 1
- Optionally, feature codes 5301 and 5325 for SAN Volume Controller fiber-optic, Fibre Channel cables, quantity 1 - 4
- Optionally, feature code 8300: redundant AC-power
switch, quantity 1
- Check that the correct part set has been shipped for the feature codes. Unless otherwise
stated, the feature code contents are in the main box.
- Feature code 0010 is preinstalled software. There is no shipped part for this software.
- Feature codes 3001 and 3002 ship the same parts. Verify that you have these parts:
- SAN Volume Controller
2145-CF8 node
- Part number 49Y4827: SAN Volume Controller
2145-CF8 Support rail kit, quantity
1
- Part number 49Y4831: SAN Volume Controller
2145-CF8 Cable-management arm
assembly, quantity 1
- Part number 31P1105: SAN Volume Controller
publications and 31P1242: ship group in a separate box
31P1105 contains:
- SAN Volume Controller Publications CD
- SAN Volume Controller Read first
- IBM Systems Safety
Notices
- IBM SAN Volume Controller Model 2145-CF8 Hardware Installation Guide
- IBM System Storage SAN Volume Controller Software Installation and Configuration Guide
- IBM SAN Volume Controller Troubleshooting Guide
- IBM SAN Volume Controller Hardware Maintenance Guide
- SAN Volume Controller License information for IBM® CIM agent and console for management GUI
- SAN Volume Controller License information for SAN Volume Controller
- SAN Volume Controller Statement of Limited
Warranty
- IPLA booklet for warranted products
- ILA booklet with pointer sheet
- IBM agreement for acquisition of
support
- IBM license information for
machine code
- Other miscellaneous flyers
- 31P1242 contains:
- Part number 31P1243: SAN Volume Controller power
cable-retention brackets, quantity 2
- Part number 31P1294: Kit containing the power and signal cable bundle, quantity 1
- The support rail kit contains a number of components within its box. Verify that you have these items:
- One left side rail
- One right side rail
- Two M6 screws in a plastic bag
- Two other screws in a plastic bag
- Feature codes 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724, 9725, 9726, and
9727 each ship a single power cable. Use the power plug that is appropriate to your location unless
you are connecting to a rack-mounted power distribution unit.
- Optional feature code 4500 ships installed in the SAN Volume Controller 2145-CF8 node, quantity 1
- Optional feature code 4601 ships installed in the SAN Volume Controller 2145-CF8 node, quantity 1 to 4
- Feature code 8115 ships in a separate box that is labeled part number 31P1319. Verify that this
box contains these items:
- 2145
UPS-1U, quantity 1
- 2145
UPS-1U output power-cable
retention-bracket kit, quantity 1
- Uninterruptible power-supply rail kit, quantity 1
- Power cable for connecting the uninterruptible power
supply
to a rack PDU, quantity 1
- Multilingual battery-reconnection flyer and other miscellaneous flyers
- Optional feature code 8300 ships in a box within the main box. Verify that the box contains
these items:
- Part number 95P5083: redundant AC-power
switch,
quantity 1
- Part number 31P0966: power cables, quantity 2
- Part number 96P1728: mounting plates, quantity 2
- Part number 12J5289: hex head screws, quantity 4
- Part number 00N8709: "c" clips, quantity 4
- Part number 24R0207: other screws, quantity 6
- Part number 31P0876: label set, quantity 1
If feature codes 5301 or 5325 was not ordered, the customer must supply their own fiber-optic or
twisted-pair Fibre Channel cables. Make sure that four cables per
node are available.
Note: Part numbers are subject to change between SAN Volume Controller releases. The part numbers listed here
might not always reflect what the customer has received.
- Read the Safety and environmental notices to ensure that you are correctly installing
the 2145
UPS-1U units.