Preparing for the SAN Volume Controller 2145-CG8 hardware installation

Ensure that the planning charts are complete and that you have received all the required parts as you prepare for the installation.

Before you begin

Figure 1 shows the major hardware components that you need.

Figure 1. Parts provided for SAN Volume Controller 2145-CG8 hardware installation in a rack
Items for installing SAN Volume Controller 2145-CG8 hardware in the rack
  •  1  SAN Volume Controller node
  •  2  SAN Volume Controller support rails (2)
  •  3  2145 UPS-1U
  •  4  2145 UPS-1U support rails (2)
  •  5  Power cable assembly
  •  6  SAN Volume Controller cable-management support arm
  •  7  SAN Volume Controller cable-management arm assembly
  •  8  Optionally, one or more redundant AC-power switches, two mounting brackets per switch, and power cables
  •  9  2145 UPS-1U cable-retention bracket
  •  10  SAN Volume Controller cable-retention brackets
  •  11  2145 UPS-1U mounting brackets

Not shown in Figure 1 are two 2145 UPS-1U input-power cables that are provided. One cable comes with the 2145 UPS-1U; it has an IEC 320-C14 plug, which is suitable for almost any rack-mounted power distribution unit. The other country-specific cable comes with the SAN Volume Controller node; this cable is intended for your country-specific power sockets. Use only one of these cables.

Before you start the installation, verify that all the parts that were ordered have been received and that all the component assemblies are complete. Verify that you know the quantity of nodes and optional features that were ordered.

Three boxes are shipped for each node: one box contains the uninterruptible power supply, one box contains the publications, and the third box contains all the other parts. A label on the third, or main, box indicates the features that were shipped.

Two SAN Volume Controller 2145-CG8 nodes might arrive on one pallet or each node might arrive separately on its own pallet.

Note:
  1. You must install at least two SAN Volume Controller nodes. Each node requires an uninterruptible power supply.
  2. Optionally, install two redundant AC-power switches to power the nodes in an I/O group through two 2145 UPS-1U units.
  3. You must ensure that you have the appropriate cables to connect the redundant AC-power switch or uninterruptible power supply to the power distribution unit. See the related links at the end of this topic for more details.

About this task

To prepare for installation:

Procedure

  1. Ensure that you have everything you need for installation, including the customer-completed planning tables and charts. The customer can obtain the planning tables and charts from www.ibm.com/support.

    The planning information provides guidelines for completing the planning tables and charts. These tables include the location of hardware, cable connection, and configuration data information that you need to complete the installation procedures. If you are connecting cables to switches that are currently in use, confirm with the customer that it is safe for you to proceed. Go no further with these instructions until you are satisfied that all the information is correct and valid.

  2. The label on the main box indicates features that were shipped. Make sure that the contents and quantity match the order.

    The following feature codes are included with each SAN Volume Controller 2145-CG8 node:

    • Feature code 0010: initial SAN Volume Controller 2145-CG8 software preinstalled on feature code 3001 and 3002.
    • One of the following:
      • Feature code 3001: initial SAN Volume Controller 2145-CG8 node, quantity 1
      • Feature code 3002: additional SAN Volume Controller 2145-CG8 node, quantity 1
    • Feature code 5608: Fibre Channel longwave small form-factor pluggable (SFP) transceiver, quantity 1 - 4.
    • Optionally, feature code 4500: Flash drive attachment, quantity 1. This feature code will be preinstalled on feature code 3001 and 3002.
    • Optionally, feature code 4602: 200 GB Flash drive, quantity 1 - 4. These feature codes will be preinstalled on feature code 3001 and 3002.
    • Optionally, feature code 4604: 400 GB Flash drive, quantity 1 - 4. These feature codes will be preinstalled on feature code 3001 and 3002.
    • Optionally, feature codes 5700 and 5711: 10 Gbps Ethernet adapter, quantity 1 and SFP transceivers, quantity 2; the single feature code contains both SFPs. Both feature codes preinstalled on feature code 3001 and 3002.
    • Optionally, feature code AHA7: 4x8 Gbps Fibre Channel HBA. This feature code will be preinstalled on feature code 3001 and 3002.
    • One of the following country-specific SAN Volume Controller 2145-CG8 power cable feature codes: 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724, 9725, 9726, or 9727.
    • Feature code 8115: 2145 UPS-1U kit, quantity 1
    • Optionally, feature codes 5305 and 5325 for SAN Volume Controller fiber-optic, Fibre Channel, or 10 Gbps Ethernet cables, quantity 1 - 6.
    • Optionally, feature code 8300: redundant AC-power switch, quantity 1.
  3. Check that the correct part set has been shipped for the feature codes. Unless otherwise stated, the feature code contents are in the main box.
    • Feature code 0010 is preinstalled software. There is no shipped part for this software.
    • Feature codes 3001 and 3002 ship the same parts. Verify that you have the listed parts:
      • SAN Volume Controller 2145-CG8 node
      • Part number 69Y1365: SAN Volume Controller 2145-CG8 Support rail kit, quantity 1
      • Part number 69Y1366: SAN Volume Controller 2145-CG8 Cable-management arm assembly, quantity 1
      • Part number 31P1105: SAN Volume Controller publications and 31P1242: ship group in a separate box
        31P1105 contains:
        • SAN Volume Controller Publications CD
        • SAN Volume Controller Read first
        • IBM Systems Safety Notices
        • IBM SAN Volume Controller Model 2145-CG8 Hardware Installation Guide
        • IBM SAN Volume Controller Troubleshooting Guide
        • IBM SAN Volume Controller Hardware Maintenance Guide
        • SAN Volume Controller License information for IBM® CIM agent and console for management GUI
        • SAN Volume Controller License information for SAN Volume Controller
        • SAN Volume Controller Statement of Limited Warranty
        • IPLA booklet for warranted products
        • ILA booklet with pointer sheet
        • IBM agreement for acquisition of support
        • IBM license information for machine code
        • Other miscellaneous flyers
      • 31P1242 contains:
        • Part number 31P1243: SAN Volume Controller power cable-retention brackets, quantity 2
        • Part number 31P1294: Kit containing the power and signal cable bundle, quantity 1
      • The support rail kit contains a number of components within its box. Verify that you have the following items:
        • One left side rail
        • One right side rail
        • Four M6 screws in a plastic ziplock bag
    • Feature codes 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724, 9725, 9726, and 9727 each ship a single power cable. Use the power plug that is appropriate to your location unless you are connecting to a rack-mounted power distribution unit.
    • Optional feature code 5608 ships uninstalled, quantity 1 - 4
    • Optional feature code 4500 ships installed in the SAN Volume Controller 2145-CG8 node, quantity 1
    • Optional feature code 4601 ships installed in the SAN Volume Controller 2145-CG8 node, quantity 1 - 4
    • Optional feature codes 5700 and 5711 ship installed in the SAN Volume Controller 2145-CG8 node, quantity 1 each
    • Feature code 8115 ships in a separate box that is labeled part number 31P1391. Verify that the box contains these items:
      • 2145 UPS-1U, quantity 1
      • 2145 UPS-1U output power-cable retention-bracket kit, quantity 1
      • Cable clip and two screws in plastic ziplock bag
      • Uninterruptible power-supply rail kit, quantity 1
      • Power cable for connecting the uninterruptible power supply to a rack; PDU, quantity 1
      • Multilingual battery-reconnection flyer and other miscellaneous flyers
      • Environmental Notices and User's Guide CD
    • Optional feature code 8300 ships in a box within the main box. Verify that the box contains the following items:
      • Part number 95P5083: redundant AC-power switch, quantity 1
      • Part number 31P0966: power cables, quantity 2
      • Part number 96P1728: mounting plates, quantity 2
      • Part number 12J5289: hex head screws, quantity 4
      • Part number 00N8709: "c" clips, quantity 4
      • Part number 24R0207: other screws, quantity 6
      • Part number 31P0876: label set, quantity 1

    If feature codes 5305 or 5325 are not ordered for Fibre Channel connection, the customer must supply their own fiber-optic Fibre Channel cables. Make sure that four cables per node are available.

    If feature codes 5700 and 5711 are ordered, and feature codes 5305 and 5325 are not ordered for Ethernet connection, the customer must supply their own OM2 or OM3 fiber-optic cables. Make sure that two cables per node are available.

    Note: Part numbers are subject to change between SAN Volume Controller releases. The part numbers listed here might not always reflect what the customer has received.
  4. Read the safety and environmental notices to ensure that you are correctly installing the 2145 UPS-1U units.