Ensure that the planning charts are complete and that you have received all the required
parts as you prepare for the installation.
Before you begin
Figure 1 shows
the major hardware components that you need.
Figure 1. Parts provided for SAN Volume Controller
2145-CG8 hardware
installation in a rack
- 1 SAN Volume Controller node
- 2 SAN Volume Controller support
rails (2)
- 3 2145
UPS-1U
- 4 2145
UPS-1U support
rails (2)
- 5 Power cable assembly
- 6 SAN Volume Controller cable-management
support arm
- 7 SAN Volume Controller cable-management
arm assembly
- 8 Optionally, one or more redundant AC-power
switches,
two mounting brackets per switch, and power cables
- 9 2145
UPS-1U cable-retention
bracket
- 10 SAN Volume Controller cable-retention
brackets
- 11 2145
UPS-1U mounting
brackets
Not shown in Figure 1 are
two 2145
UPS-1U input-power
cables that
are provided. One cable comes with the 2145
UPS-1U;
it has an IEC 320-C14 plug, which is suitable for almost any rack-mounted power distribution unit.
The other country-specific cable comes with the SAN Volume Controller node;
this cable is intended for your country-specific power sockets. Use
only one of these cables.
Before you start the installation,
verify that all the parts that were ordered have been received and
that all the component assemblies are complete. Verify that you know
the quantity of nodes and optional features that were ordered.
Three
boxes are shipped for each node: one box contains the uninterruptible power
supply,
one box contains the publications, and the third box contains all
the other parts. A label on the third, or main, box indicates the
features that were shipped.
Two SAN Volume Controller
2145-CG8 nodes
might arrive on one pallet or each node might arrive separately on
its own pallet.
Note: - You must install at least two SAN Volume Controller nodes.
Each node requires an uninterruptible power
supply.
- Optionally, install two redundant AC-power
switches to
power the nodes in an I/O group through two 2145 UPS-1U units.
- You must ensure that you have the
appropriate cables to connect the redundant AC-power
switch or uninterruptible power
supply to
the power distribution unit.
See the related links at the end of this topic for more details.
About this task
To prepare for
installation:
Procedure
- Ensure that you have everything you need for
installation, including the customer-completed planning tables and charts. The customer can obtain
the planning tables and charts from www.ibm.com/support.
The planning information provides
guidelines for completing the planning tables and charts. These tables include the location of
hardware, cable connection, and configuration data information that you need to complete the
installation procedures. If you are connecting cables to switches that are currently in use, confirm
with the customer that it is safe for you to proceed. Go no further with these instructions until
you are satisfied that all the information is correct and valid.
- The label on the main box indicates features that were
shipped. Make sure that the contents and quantity match the order.
The following feature codes are included with
each SAN Volume Controller
2145-CG8 node:
- Feature code 0010: initial SAN Volume Controller
2145-CG8 software
preinstalled on feature code 3001 and 3002.
- One of the following:
- Feature code 3001: initial SAN Volume Controller
2145-CG8 node,
quantity 1
- Feature code 3002: additional SAN Volume Controller
2145-CG8 node,
quantity 1
- Feature code 5608: Fibre Channel longwave small form-factor pluggable
(SFP) transceiver, quantity 1 - 4.
- Optionally, feature code 4500: Flash
drive attachment,
quantity 1. This feature code will be preinstalled on feature code
3001 and 3002.
- Optionally, feature code 4602: 200 GB Flash
drive,
quantity 1 - 4. These feature codes will be preinstalled on feature
code 3001 and 3002.
- Optionally, feature code 4604: 400 GB Flash
drive,
quantity 1 - 4. These feature codes will be preinstalled on feature
code 3001 and 3002.
- Optionally, feature codes 5700 and 5711: 10
Gbps Ethernet adapter, quantity 1 and SFP transceivers, quantity 2;
the single feature code contains both SFPs. Both feature codes preinstalled
on feature code 3001 and 3002.
- Optionally, feature code AHA7: 4x8 Gbps Fibre Channel HBA. This
feature code will be preinstalled on feature code 3001 and 3002.
- One of the following country-specific SAN Volume Controller
2145-CG8 power
cable feature codes: 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721,
9722, 9723, 9724, 9725, 9726, or 9727.
- Feature code 8115: 2145
UPS-1U kit,
quantity 1
- Optionally, feature codes 5305 and 5325 for SAN Volume Controller fiber-optic,
Fibre Channel, or 10 Gbps Ethernet cables, quantity 1 - 6.
- Optionally, feature code 8300: redundant AC-power
switch,
quantity 1.
- Check that the correct part set has been shipped for the
feature codes. Unless otherwise stated, the feature code contents
are in the main box.
- Feature code 0010 is preinstalled software. There is no shipped
part for this software.
- Feature codes 3001 and 3002 ship the same parts. Verify that you
have the listed parts:
- SAN Volume Controller
2145-CG8 node
- Part number 69Y1365: SAN Volume Controller
2145-CG8 Support
rail kit, quantity 1
- Part number 69Y1366: SAN Volume Controller
2145-CG8 Cable-management
arm assembly, quantity 1
- Part number 31P1105: SAN Volume Controller publications
and 31P1242: ship group in a separate box
31P1105 contains:
- SAN Volume Controller Publications
CD
- SAN Volume Controller Read
first
- IBM Systems Safety
Notices
- IBM SAN Volume Controller Model 2145-CG8 Hardware Installation Guide
- IBM SAN Volume Controller Troubleshooting Guide
- IBM SAN Volume Controller Hardware Maintenance Guide
- SAN Volume Controller License
information for IBM® CIM
agent and console for management GUI
- SAN Volume Controller License
information for SAN Volume Controller
- SAN Volume Controller Statement
of Limited Warranty
- IPLA booklet for warranted products
- ILA booklet with pointer sheet
- IBM agreement
for acquisition of support
- IBM license
information for machine code
- Other miscellaneous flyers
- 31P1242 contains:
- Part number 31P1243: SAN Volume Controller power
cable-retention brackets, quantity 2
- Part number 31P1294: Kit containing the power and signal cable
bundle, quantity 1
- The support rail kit contains a number of components within its
box. Verify that you have the following items:
- One left side rail
- One right side rail
- Four M6 screws in a plastic ziplock bag
- Feature codes 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721,
9722, 9723, 9724, 9725, 9726, and 9727 each ship a single power cable.
Use the power plug that is appropriate to your location unless you
are connecting to a rack-mounted power distribution unit.
- Optional feature code 5608 ships uninstalled, quantity 1 - 4
- Optional feature code 4500 ships installed in the SAN Volume Controller 2145-CG8
node, quantity 1
- Optional feature code 4601 ships installed in the SAN Volume Controller 2145-CG8
node, quantity 1 - 4
- Optional feature codes 5700 and 5711 ship installed in the SAN
Volume Controller 2145-CG8 node, quantity 1 each
- Feature code 8115 ships in a separate box that is labeled part
number 31P1391. Verify that the box contains these items:
- 2145
UPS-1U,
quantity 1
- 2145
UPS-1U output
power-cable retention-bracket kit, quantity 1
- Cable clip and two screws in plastic ziplock bag
- Uninterruptible power-supply rail kit, quantity 1
- Power cable for connecting the uninterruptible power
supply to
a rack; PDU, quantity 1
- Multilingual battery-reconnection flyer and other miscellaneous
flyers
- Environmental Notices and User's Guide CD
- Optional feature code 8300 ships in a box within the main box.
Verify that the box contains the following items:
- Part number 95P5083: redundant AC-power
switch,
quantity 1
- Part number 31P0966: power cables, quantity 2
- Part number 96P1728: mounting plates, quantity 2
- Part number 12J5289: hex head screws, quantity 4
- Part number 00N8709: "c" clips, quantity 4
- Part number 24R0207: other screws, quantity 6
- Part number 31P0876: label set, quantity 1
If feature codes 5305 or 5325 are not ordered for Fibre Channel
connection, the customer must supply their own fiber-optic Fibre Channel
cables. Make sure that four cables per node are available.
If
feature codes 5700 and 5711 are ordered, and feature codes 5305 and
5325 are not ordered for Ethernet connection, the customer must supply
their own OM2 or OM3 fiber-optic cables. Make sure that two cables
per node are available.
Note: Part numbers are subject to change
between SAN Volume Controller releases.
The part numbers listed here might not always reflect what the customer
has received.
- Read the safety and environmental notices
to ensure that you are correctly installing the 2145
UPS-1U units.