You can remove the operator-information
panel assembly on a SAN Volume Controller 2145-CG8 or 2145-CF8
node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Take precautions to avoid damage from static electricity.
Wear an anti-static wrist strap and use a static-protected mat or
surface.
About this task
This service action requires you to:
- Turn off the node.
- Disconnect the power cables.
Make careful note of the layout of the cables as you go
through this procedure as you must replace them in the same position
when you replace the operator-information
panel assembly.
Perform
the following steps to remove the operator-information
panel:
Procedure
- Read the safety information to which Preparing to remove and replace parts refers.
- Follow the procedure in MAP 5350: Powering off a node to verify that hosts will not
lose access to data in volumes before you power off the node.
- Slide the node out on its slide rails to the fully extended position.
You can accomplish most service actions when the node is fully extended
from the rack on its slide rails. You can leave the Fibre Channel and Ethernet cables connected, if you
are using the cable-management arm and if you are not removing the node from the rack. If the location of the node in the rack is too high or too low to work
comfortably, you can remove the node from the rack.
- When the node is completely turned
off, remove the cable-retention brackets and disconnect the power
cables, as described in Removing the cable-retention bracket.
- Optional: If you must remove the node from
the rack to work on it, perform the following procedure to remove
all cables and remove the node from the rack:
- To make sure that you can replace all cables in the same ports from which they
were removed, label the port position of each Fibre Channel and Ethernet cable; then remove all
cables from the back of the node.
- Remove the node from the rack and place
it on a flat, static-protective surface. See Removing a node from a rack.
- From the rear of the operator-information panel assembly,
disconnect the cable.
- Use an object to push down on the release
tab ( 2 in Figure 1).
Hold
down the release tab and push the blue push point on the rear of the
panel toward the front of the node.
Figure 1. Using the release tab to remove the SAN Volume Controller 2145-CG8 or 2145-CF8 operator-information
panel
- 1 Operator-information panel
- 2 Release tab
- From the front of the node, carefully pull the assembly
( 1 ) out of the node while you move the
assembly slightly from side to side.
- If you are instructed to return the operator-information
panel assembly, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.