You can remove the fan bracket on a SAN Volume Controller
2145-DH8 node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Take precautions to avoid damage from static electricity.
Wear an anti-static wrist strap and use a static-protected mat or
surface.
About this task
This service action assumes:
- The node is turned off. If you must turn off the node, ensure that hosts
will not lose access to data in volumes, as described in MAP 5350: Powering off a node.
- The power cables are disconnected.
- The top cover is removed.
- The air baffle is removed.
- The PCI express rise-card assemblies are removed.
- The fans are removed.
Procedure
- Remove
the cables that are routed over the fan bracket.
- Press the fan-bracket release latches toward each other
and lift the fan bracket out of the server, as shown in Figure 1.
Figure 1. Removing
the fan bracket