About this task
This service action requires you to remove the cover and
complete the following actions:
- Turn the node off.
- Disconnect the power cables.
- Disconnect the data cables.
To remove the SAN Volume Controller 2145-CG8
or 2145-CF8 high-speed
SAS adapter assembly, complete the following steps:
- Read the safety information to which Preparing to remove and replace parts refers.
- Follow the procedure in MAP 5350: Powering off a node to verify that hosts will not
lose access to data in volumes before you power off the node.
- Slide the node out on its slide rails to the fully extended position.
You can accomplish most service actions when the node is fully extended
from the rack on its slide rails. You can leave the Fibre Channel and Ethernet cables connected, if you
are using the cable-management arm and if you are not removing the node from the rack. If the location of the node in the rack is too high or too low to work
comfortably, you can remove the node from the rack.
- When the node is completely turned
off, remove the cable-retention brackets and disconnect the power
cables, as described in Removing the cable-retention bracket.
- To make sure that you can replace all cables in the same ports from which they
were removed, label the port position of each Fibre Channel and Ethernet cable; then remove all
cables from the back of the node.
- Optional: Remove the node from the rack and place
it on a flat, static-protective surface. See Removing a node from a rack.
- Remove the top cover, as described in Removing the top cover: 2145-CG8 or 2145-CF8.
- Remove the two M3 screws that attach the adapter
assembly to the back rail.
The high-speed SAS adapter
assembly and the Fibre Channel adapter
assembly each attach to the back rail with two screws, as shown in
the partial view of the rail with the high-speed SAS adapter assembly
attached in Figure 1.
Figure 1. High-speed SAS adapter
assembly mounted in the back rail of the SAN Volume Controller 2145-CG8 or 2145-CF8
- After removing the back-rail retaining screws
for the adapter assembly, grasp the riser-card assembly at the rear
edge and lift to remove the assembly, as shown in Figure 2.
Figure 2. Removing the high-speed
SAS riser-card assembly for the SAN Volume Controller 2145-CG8
or 2145-CF8
- Grasp the high-speed SAS adapter riser-card assembly by
its top edge or upper corners and pull the card up out of the slot
2 riser-card connector.
Note: Do not power
on the node with nothing connected to the system planar PCI slot 2.
If you are replacing the SAS adapter (supported only on CG-8), insert
the replacement adapter. If you are not replacing the SAS adapter,
either insert a high-speed SAS adapter, or a riser card. If you need
a riser card and do not have one, you can remove the riser card from
the 10 Gbps Ethernet card that you just removed.
When looking
from the back, the slot 2 connector is the connector on the right.
The 4-port Fibre Channel adapter attaches
to the slot 1 connector on the left side of the system board, when
looking from the back.
- Remove the high-speed SAS adapter cable from
the adapter.
- Place the high-speed SAS adapter riser-card assembly on
a flat, static-protective surface.
- If you are instructed to return the high-speed SAS adapter
riser-card assembly, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.