You can remove and replace either of the two 675-watt hot-swap redundant power supplies
in the SAN Volume Controller 2145-CG8 or 2145-CF8 node. These
redundant power supplies operate in parallel, one continuing to power the node if the other
fails.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Ensure that you are aware of the procedures for handling
static-sensitive devices before you remove the power supply.
About this task
This service action requires you to complete the following actions:
- Optionally, turn the node off.
- Disconnect the power cable on each power supply that you are removing.
Important: You can hot swap the power supply.
However, using MAP 5350 to power off the node through proven methods
avoids risking an abrupt power failure on the node, which avoids the
possible corruption of data.
To remove the SAN Volume Controller 2145-CG8 or 2145-CF8
power supply, complete the following steps.
Procedure
- Read the safety information to which Preparing to remove and replace parts refers.
- Optional: Follow the procedure in MAP 5350: Powering off a node to verify that hosts will not
lose access to data in volumes before you power off the node.
Important: If you decide to hot swap the power supply, use MAP 5350 to make all of the
necessary checks that ensure that the partner node in the I/O group can take over all I/O group
operations, if necessary, and that there are no dependent volumes on the node. With the partner node
available and no dependent volumes on the node, you do not lose access to data if this node
accidentally powers off.
- Pull back the cable-management arm if you are working from the rear of
the rack, or slide the node out of the rack to the fully extended rail position if you are working
from the front.
- Remove the cable-retention bracket and the
power cord from the power supply that you are replacing, as described
in Removing the cable-retention brackets: 2145-CG8 or 2145-CF8.
- To remove the power supply 1 , press and hold the release tab
2 to the left. Grasp the handle 3 on the
rear of the power supply, as shown in Figure 1, and pull
the power supply out of the node.
Figure 1. SAN Volume Controller 2145-CG8 or 2145-CF8 power
supply
- 1 Power supply
- 2 Power-supply release tab
- 3 Power-supply handle
- If you are instructed to return the power supply, follow all packaging instructions. Use any
packaging materials for shipping that are supplied to you.