An authorized IBM service provider can replace the 10 gigabits
per second (Gbps) Ethernet riser-card assembly into the SAN Volume Controller
2145-CG8 node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Figure 1 shows the connectors on the rear
of the
SAN Volume Controller
2145-CG8 node.
Figure 1. Connectors on the rear of the 2145-CG8 node
- 1 Fibre Channel port 1
- 2 Fibre Channel port 2
- 3 Fibre Channel port 3
- 4 Fibre Channel port 4
- 5
10 Gbps Ethernet port 1
- 6
10 Gbps Ethernet port 2
- 7 Power connector 1
- 8 Power connector 2
- 9 Serial port for UPS communications (RS232)
- 10 1 Gbps Ethernet port 2
- 11 1 Gbps Ethernet port 1
About this task
This service action assumes that you have removed the top cover and that the following actions
are completed:
- The node is off.
- The power cables are disconnected.
- The data cables are disconnected.
To replace the 10 Gbps Ethernet riser-card assembly on a 2145-CG8 node, perform the following
steps:
Procedure
- If present, remove both Ethernet small form-factor pluggable (SFP) transceivers
before replacing the Ethernet riser-card assembly, as described in Removing and replacing an Ethernet SFP transceiver.
- Grasp each end of the Ethernet riser-card assembly, tilt
the Ethernet riser-card assembly so that the side with the PCI riser
card is higher than the opposite side, and the back is higher than
the front.
- Locate the cage that houses the Ethernet SFP transceivers
through the hole in the back of the node.
- Align the 10 Gbps Ethernet riser-card assembly connector
with the PCI slot 2 connector on the system board, as shown in Figure 2.
Figure 2. Replacing the 10 Gbps Ethernet riser-card assembly for the 2145-CG8
- 1 PCI slot 2 riser-card connector
- 2 10 Gbps Ethernet riser-card assembly
When looking from the back, the PCI slot 1 connector is
the connector on the left. The 10 Gbps Ethernet riser-card assembly
attaches to the PCI slot 2 connector on the right side of the system
board, when looking from the back.
- Press down on the top of the Ethernet riser-card assembly
until the card settles in the slot.
- Anchor the Ethernet riser-card assembly using two fastening
screws from the back of the node, as shown in the cutaway view of
a section of the rail in Figure 3.
Figure 3. 2145-CG8 10 Gbps
Ethernet riser-card assembly with cutaway view of back rail
- 1 10 Gbps Ethernet port 1
- 2 10 Gbps Ethernet port 2
- 3 Back-rail retaining screws
- Install both SFP transceivers into the Ethernet riser-card
assembly, as described in Removing and replacing an Ethernet SFP transceiver.
- If you did not do so as part of the procedure for replacing
the Ethernet SFP transceivers, make sure that all cables, adapters,
and other components are installed and seated correctly and that you
have not left loose tools or parts inside the node. Make sure that
all internal cables are correctly routed.
- If you did not do so as part of the procedure for replacing
the Ethernet SFP transceivers, replace the top cover, following the
procedure in Replacing the top cover and
being careful to reattach the fiber optic cable to Ethernet port 1
before replacing the serial cable connecting the node to the UPS.
After following the procedure to replace the top cover, the
node is installed in the rack, all cables are reconnected, and the
node is turned on.