Replacing the operator-information panel assembly: 2145-SV1

You can replace the operator-information panel on a SAN Volume Controller 2145-SV1 node.

Before you begin

DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Safety icons for multiple power cords

Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface.

About this task

This service action assumes that the following conditions are met.
Attention: Failure to install or remove the operator-information panel cable with care can damage the connectors on the system board. Damage to the connectors might require replacing the system board.

Procedure

To replace the operator-information panel, complete the following steps:

  1. Read the safety information.
  2. From the front of the node, slide the operator-information panel into the node until it clicks into place, as shown in Figure 1.
    Figure 1. Replacing the 2145-SV1 operator-information panel
    Replacing the 2145-SV1 operator-information panel
  3. Use the two screws to reattach the operator-information panel assembly.
  4. Inside the node, connect the cable to the rear of the operator-information panel assembly.
  5. Replace the top covers, as described in Replacing the top covers: 2145-SV1.
  6. If you removed the node from the rack, replace it in the rack, as described in Replacing a node in a rack: 2145-SV1.
  7. If you removed any Fibre Channel or Ethernet cables, replace them in the same ports from which they were removed.
  8. Replace the power cords. The node turns on when power is restored.