Replacing a power supply: 2145-CG8 or 2145-CF8
You can replace either of the two 675-watt hot-swap redundant power supplies in the SAN Volume Controller 2145-CG8 or 2145-CF8 node. These redundant power supplies operate in parallel, one continuing to power the node if the other fails.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
![]() |
or | ![]() |
or | ![]() |
Ensure that you are aware of the procedures for handling static-sensitive devices before you replace the power supply.
About this task
Important: You can hot swap the power supply. However, using MAP 5350 to power off the
node through proven methods avoids risking an abrupt power failure on the node, which avoids the
possible corruption of data. This procedure assumes that you have turned off the node using MAP
5350, or that if you did not turn off the node, you used MAP 5350 to ensure that the data is
mirrored and synchronized, and that there are no dependent volumes. See MAP 5350: Powering off a node.
To replace the SAN Volume Controller 2145-CG8 or 2145-CF8 power supply, complete the following steps.