Replacing the microprocessor: 2145-CG8 or 2145-CF8
You can replace the microprocessor on a SAN Volume Controller 2145-CG8 or 2145-CF8 node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple
power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
![]() |
or | ![]() |
or | ![]() |
Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface.
To correctly perform this task, you must have alcohol wipes and thermal grease available. If you do not already have them, order these separately.
About this task
This procedure is based on the following assumptions:
- You are a trained IBM® service technician.
- You removed all power from the node.
- You removed the node from the rack.
- You removed the top cover of the node.
- You removed the microprocessor that is being replaced.
Furthermore, always replace the microprocessor in microprocessor socket one.
Attention: Removing the heat sink from
the microprocessor destroys the even distribution of the thermal grease
and requires replacing the thermal grease.
Perform the
following steps to replace the microprocessor and heat sink:If the thermal-grease protective cover (for example, a plastic cap or tape liner) is removed from the heat sink, do not touch the thermal grease on the bottom of the heat sink or set down the heat sink.