Installing the 2145 UPS-1U cable-retention bracket

The 2145 UPS-1U cable-retention bracket ensures that the power cable connection between the 2145 UPS-1U and the SAN Volume Controller node is stable.

Before you begin

Install the bracket after you install the power and signal cable assembly that was supplied with the node to connect the 2145 UPS-1U and the node.

About this task

You can attach the bracket by completing the following steps:

Procedure

  1. Install the power cable into the rightmost power outlet on the rear of the 2145 UPS-1U.
  2. Remove the bracket and the two screws (shown in Figure 1) from the packaging.
    Figure 1. 2145 UPS-1U power cable-retention bracket hardware
    This figure shows the 2145 UPS-1U cable-retention bracket hardware
  3. Place the bracket over the power outlets on the right rear of the 2145 UPS-1U, so that the two screw holes line up.
  4. Position the bracket with the power cable protruding through the rightmost slot in the bracket.
  5. Secure the bracket in place with one screw on each side, as shown in Figure 2.
    Figure 2. 2145 UPS-1U power cable-retention bracket
    2145 UPS-1U power cable-retention bracket