710   The SAS adapter that was previously present has not been detected.

Explanation

A SAS adapter that was previously present has not been detected. The adapter might not be correctly installed or it might have failed.

Data:

  • A number indicating the adapter location. The location indicates an adapter slot. See the node description for the definition of the adapter slot locations.

User response

  1. If possible, use the management GUI to run the recommended actions for the associated service error code.
  2. Possibilities:
    • If the adapter has been intentionally removed, use the management GUI recommended actions for the service error code, to acknowledge the change.
    • Use the remove and replace procedures to remove and open the node and check the adapter is fully installed.
    • If the previous steps have not isolated the problem, use the remove and replace procedures to replace the adapter. If this does not fix the problem, replace the system board.

Possible Cause-FRUs or other cause:

  • High-speed SAS adapter