SAN Volume Controller 2145-24F and 2145-12F expansion canister SAS ports and indicators
Two SAS ports are located in the rear of the SAN Volume Controller 2145-24F and 2145-12F expansion canister.
SAS ports are numbered at the bottom of the port, with 1 on the left and 2 on the right, as shown in Figure 1. Use of port 1 is required. Port 2 is not used. Port 1 connects four data channels.
Figure 1. SAS ports and LEDs at rear of expansion canister

Figure 1 has callouts
to show the location of the LEDs and the port for SAS port 1:
- 1 Port 1 LEDs
- 2 Port 1 12 Gbps SAS port
Table 1 describes
LED states for each of the two LEDs per SAS port. The link LED is
on the left of each set of ports.
| Name | Color | State | Meaning |
|---|---|---|---|
| SAS Port 1 Link | Green | OFF | No physical link connection on any phys. The connection is down. |
| ON | There is a connection on at least one physical lane. At least one of the lanes to that connector is up. | ||
| SAS Port 1 Fault | Amber | OFF | No fault. All four physical lanes have a link connection. |
| ON | This value indicates a number of different error conditions:
|
||
| SAS Port 2 Link | Green | OFF | No link connection on any physical lanes. The connection is down. |
| ON | There is a connection on at least one physical lane. At least one of the lanes to that connector is up. | ||
| SAS Port 2 Fault | Amber | OFF | No fault. All four physical lanes have a link connection. |
| ON | This value indicates a number of different error conditions:
|