Powering off the expansion enclosure: 2145-92F
Before you power down a 2145-92F expansion enclosure, review the following procedure.
Before you begin
When you power off an expansion enclosure, the drives in that enclosure are no longer available to the node. The SAS chain also breaks. Any expansion enclosures that are beyond the enclosure that is powered down are also disconnected from the node.
Before you power off an enclosure, use the management GUI to show the volumes that depend on that enclosure. In the system view, select the expansion enclosure to be powered off. Then, select Dependent Volumes. If no configuration changes are made, other volumes remain available to the system.
Procedure
- Stop all I/O to the system from hosts that access the expansion enclosure.
- Unmount any associated file systems.
- Wait 5 minutes for all write data to be flushed to the drives.
- Unplug both of the power cords from the rear of the expansion enclosure to remove all power from the enclosure.