Removing a power supply: 2145-SV1

You can remove either of the two hot-swap redundant power supplies in the SAN Volume Controller 2145-SV1 node. Redundant power supplies operate in parallel, one continuing to power the node if the other fails.

Before you begin

DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Safety icons for multiple power cords

Ensure that you are aware of the procedures for handling static-sensitive devices before you remove the power supply unit (PSU).

Procedure

  1. Read the safety information in Preparing to remove and replace parts.
  2. If only one power supply is installed, turn off the node and peripheral devices and disconnect all power cords.
  3. If the node is in a rack, pull back the cable management arm to gain access to the rear of the server and the power supply.
  4. Press and hold the release tab to the left. Figure 1 shows the release tab for power supply unit 1.
    Figure 1. Release in the 2145-SV1 power supply
    Removing the 2145-SV1 power supply
  5. Grasp the handle and pull the power supply out of the node, as shown in Figure 2.
    Figure 2. Removing the 2145-SV1 power supply
    Removing the 2145-SV1 power supply
  6. If you are instructed to return the power supply, follow all packaging instructions. Use any packaging materials for shipping that are supplied to you.