Removing and replacing a Trusted Platform Module: 2145-SV1

You might need to replace the Trusted Platform Module (TPM) in a SAN Volume Controller 2145-SV1 node.

Before you begin

DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
Safety icons for multiple power cords
  • Read the safety information in Preparing to remove and replace parts.
  • Use the management GUI to see whether this node has dependent volumes or enter the following lsdependentvdisks command:
    lsdependentvdisks -node node_id

    Ensure that each host has an active path to the volume through the node that is not that is powered off.

    CAUTION:
    If all of the TPMs are changed at the same while no active nodes are in the system, the system might not recover properly. Change the TPM in only one node at a time. Then, ensure that the node status is active again before you attempt to change the TPM in another node.

About this task

To replace a faulty Trusted Platform Module (TPM) with a new one received from FRU stock, use this procedure.

Procedure

  1. Follow the procedure in MAP 5350: Powering off a node to verify that hosts do not lose access to data in volumes before you power off the node.
    Attention: To prevent loss of access to data, make sure that powering off this node does not cause volumes to go offline.

Removing the TPM

  1. Disconnect each power supply unit in the node from its power outlet so that the node is powered off.
  2. Confirm that all the LEDs on the rear of the enclosure are off.
  3. Disconnect all SAS cords from the back of the enclosure.
  4. Slide the node out on its slide rails to the fully extended position.
  5. Remove the top back cover, as described in Removing the top covers: 2145-SV1.
  6. Locate the TPM on the main board, as shown in Figure 1 .
    Figure 1. Locating the TPM on the main board of a 2145-SV1 node
    Location of the TPM on the main board of a 2145-SV1 node
  7. Push out the locking clips on the side of the TPM to free it, as shown in Figure 2.
    Figure 2. Removing the TPM from the main board of a 2145-SV1 node
    Remove the TPM from the main board of a 2145-SV1 node
  8. Lift the TPM up and out of the slot.

Replacing the TPM

  1. Insert the new TPM.
  2. Push the locking clips in on each side of the TPM socket.
  3. Replace the top back cover, as described in Replacing the top covers: 2145-SV1.
  4. Slide the node back into the rack, as described in Replacing a node in a rack: 2145-SV1.
  5. Reconnect the SAS cables to the rear of the enclosure.
  6. Reattach the power cables and reconnect each power supply unit to the power source.
  7. Confirm that the enclosure is powered on by checking that the LEDs on the rear of the enclosure are on.