Removing the operator-information panel assembly: 2145-DH8

You can remove the operator-information panel assembly on a SAN Volume Controller 2145-DH8 node.

Before you begin

DANGER
Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003)
Multiple plugs: first set
or
Multiple plugs: second set
or
Multiple plugs: third set

Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface.

About this task

This service action assumes:
  • The node is turned off. Ensure that the data is mirrored and synchronized, and that there are no dependent volumes. See MAP 5350: Powering off a node.
  • The power cables are disconnected.
  • The top cover is removed.

Procedure

To remove the operator-information panel assembly, complete the following steps:

  1. Read the safety information.
  2. Inside the node, disconnect the cable from the rear of the operator information panel assembly.
  3. To remove the operator-information panel, press the release latch for the light panel diagnostics panel.
  4. From the front of the node, slide the operator-information panel assembly out of the node, as shown in Figure 1.
    Figure 1. Removing the 2145-DH8 operator-information panel assembly
    Removing the 2145-DH8 operator-information panel assembly