Removing the 240 VA safety cover: 2145-DH8
You can remove the 240 VA safety cover on a SAN Volume Controller 2145-DH8 node.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple AC
power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power
cords and power cables. (L003)
![]() |
or | ![]() |
or | ![]() |
Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface.
About this task
This service action assumes:
- The node is turned off. If you must turn off the node, ensure that hosts will not lose access to data in volumes, as described in MAP 5350: Powering off a node.
- The power cords and external cables are disconnected.
- The top cover is removed.
- The air baffle is removed.
- The PCI express rise-card assemblies are removed.

Procedure
- Read the safety information.
- Pull the server out of the rack.
- Disconnect the hard disk drive backplane power cables from the connector in front of the safety cover.
- Remove the screw from the safety cover.
- Slide the cover forward to disengage it from the system board, and then lift it out of the server, as shown in Figure 1.
- If you are instructed to return the 240 VA safety cover, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.