You can update a
flash drive by downloading and
applying firmware updates.
About this task
This procedure updates
firmware on an flash drive that is
either internal to a supported node or is in an enclosure that is directly attached to a node.
If the update would cause any volumes to go
offline, the force option is required.
To update drive firmware for all drives by using the management GUI, select . You can also update individual drives.
To update drive firmware by using the CLI,
follow these steps:
Procedure
-
Run the following command for the drive that you are updating.
lsdependentvdisks -drive drive_id
If any volumes
are returned, continuing with this procedure takes the volumes offline. To avoid losing access
to data, resolve any redundancy errors to remove this problem before you continue with the
update procedure.
-
Locate the firmware update file at the
following website:
This website also provides a link to the Software Update Test Utility. This utility indicates
whether any of your drives are not running at the latest level of firmware.
-
Using scp or pscp, copy the firmware update file and the Software Update Test Utility package to the
/home/admin/upgrade directory by using the management IP address.
-
Run the applydrivesoftware command. You must specify the firmware update file, the firmware type, and either a
list of drive IDs or the parameter -all to specify all drives:
applydrivesoftware -file name -type firmware -drive drive_id
To
apply the
update even if it causes one or
more volumes to go offline, specify the
-force option. Using the
-force option can cause the loss of data.
Use the
-force option under the direction of a service representative.
Attention: Do not use the -type fpga option, which updates Field Programmable Gate Array (FPGA)
firmware, unless directed to do so by a service representative.