Procedure: Removing and replacing the lid of a node canister
To remove or replace the lid of a node canister, use this procedure.
About this task
It might be necessary to service a node canister or to
replace a part that is either a customer replaceable unit (CRU) or
a field replaceable unit (FRU) that is contained within the canister.
To remove the lid of a node canister, follow these steps.
Attention: The lid of a node canister can be removed only after
the canister was removed from its enclosure. Unless you are otherwise
instructed, follow the procedure for removing a node canister to remove
a node canister from its enclosure.
To remove a canister
lid:
Place the node canister upside down on a work surface, with the
release levers facing toward you.
Open the cover of the canister by depressing the recessed, blue
touch points on the lid and sliding the lid away from you, as shown
in Figure 1.
To replace a canister lid, slide the canister lid onto
the canister until the catch clicks and the lid edges are flush with
the canister. Figure 1. Replacing the canister cover