To provide system management connectivity for the system, connect Ethernet cables to
Ethernet port 1 of both node canisters in the control enclosure.
Procedure
To install the Ethernet cables, complete the following steps.
Connect Ethernet port 1 of each node canister in the system to the IP network that will
provide connection to the system management interfaces, as shown in Figure 1 and Figure 2.
This port can also be used for iSCSI connectivity to the system by hosts on the network.
Where more than one control enclosure is present in the system, ensure port 1 of every node
canister is connected to the same network to provide access if the configuration node
fails.Figure 1. Ethernet ports on canister 1 (upper canister)
Figure 2. Ethernet ports on canister 2 (lower canister)
Optionally, connect Ethernet port 2 of each node canister in the system to a second IP
network that will provide redundant connection to the system management interfaces.
This port can also be used for iSCSI connectivity to the system by hosts on the network.
If there is more than one control enclosure in the system, ensure that port 2 of every node
canister is connected to the same network to provide access if the configuration node
fails.