The indicators on the left end cap of the control enclosure provide an overview of the
enclosure status.
Labels and indicators on the left end cap of the control enclosure provide information about the
enclosure status.
When multiple enclosures are in a rack, the serial number is used to identify the enclosure that is
being referenced. Figure 1. Left enclosure end cap
Table 1 summarizes the possible
meanings of each indicator.
Table 1. Summary of LED Indicators
Indicator Name
Color
Symbol
Meaning
Control enclosure operational
Green
Off - The enclosure isn’t receiving AC power or it’s running on battery.
Slow flash - The main CPU isn’t running or all canisters are in X86 standby mode.
On - The CPU is active (not in standby mode) on at least one node canister.
Identify enclosure.
Blue
Off - Default
On - The light identifies the enclosure. The LED can be turned on or off by the
chenclosure command.
Enclosure fault
Amber
Off - No faults detected.
On
The enclosure is coming up.
A canister, drive, PSU, or fan assembly has an error.
A drive failed; the fault LED is also lit on the failed drive.