Each enclosure is provided power through two power supplies. Either power supply unit
can power the enclosure independently if there is a loss of input power to the other power supply
in the enclosure.
Plan to connect the power cords of the power supplies on the left side of the enclosures
(when viewed from the rear) to one power source, and the power cords of the power supplies on the
right side of the enclosures to another power source.
Attention: The power cord is the
main power disconnect. Ensure that the socket outlets are located near the equipment and are easily
accessible.
Figure 1 shows the rear view of a Storwize® V7000 Gen2 or Storwize V7000 Gen2+ control enclosure with the power
supplies 2 at each end of the enclosure.Figure 1. Rear view of the power supplies on a Storwize V7000 Gen2 or Storwize V7000 Gen2+ control enclosure
1 Node canisters
2 Power supply units: power supply 1 (left), power supply 2
(right)
Figure 2 shows the back of a
Storwize V7000 Gen3
control enclosure. Each PSU is located on the sides of the control enclosure. Figure 2. Rear view a Storwize V7000 Gen3
control enclosure
Figure 3 shows the location of the power supply units on a 2U
expansion enclosure.Figure 3. Rear view of the power supplies on a 2U expansion enclosure
1 Expansion canisters
2 Power supply units
The power supply units in a control enclosure are not interchangeable with the power supply
units in an expansion enclosure.