lsenclosurefanmodule
Use the lsenclosurefanmodule command to report the status of each fan module and the contained fans in an enclosure.
Syntax
Parameters
- -fanmodule fanmodule_id
- (Optional) Specifies the ID of the fan module for which data is displayed. The
possible values are
1or2, and any other value returns no output. - -nohdr
- (Optional) By default, headings are displayed for each column of data in a concise
style view, and for each item of data in a detailed style view. The
-nohdr parameter suppresses the display of these
headings.Note: If there is no data to be displayed, headings are not displayed.
- -delim delimiter
- (Optional) By default in a concise view, all columns of data are space-separated. The
width of each column is set to the maximum width of each item of data. In a detailed
view, each item of data has its own row, and if the headers are displayed, the data is
separated from the header by a space. The -delim parameter
overrides this behavior. Valid input for the -delim parameter is a
1-byte character. If you enter
-delim :on the command line, the colon character (:) separates all items of data in a concise view; for example, the spacing of columns does not occur. In a detailed view, the data is separated from its header by the specified delimiter. - enclosure_id
- (Optional) Specifies the ID of the enclosure for which data is displayed.
Description
The command reports status for fan modules and the contained fans in an enclosure.This table provides the possible
values that are applicable to the attributes that are displayed as data in the output views.
| Attribute | Value |
|---|---|
| enclosure_id | Indicates the enclosure ID of the enclosure that contains the fan module. |
| fan_module_id | Indicates the fan module ID of the fan module that is in the
enclosure. The possible values are 1 or
2. |
| status | Indicates the combined status of the fan module and any
contained fans. The values are:
|
| error_sequence_number | Indicates the event log sequence number of the current event that is logged against the fan module. It is blank if there is no current event. |
| FRU_part_number | Indicates the part number of the fan module. |
| FRU_identity | Indicates the FRU identity of the fan module. |
| fault_LED | Indicates the status of the fault light-emitting diode (LED)
on the fan module:
|
An invocation example
lsenclosurefanmoduleThe resulting output:
enclosure_id fan_module_id status
1 1 online
1 2 online
2 1 online
2 2 onlineAn invocation example
lsenclosurefanmodule 2The resulting output:
enclosure_id fan_module_id status
2 1 online
2 2 onlineAn invocation example
lsenclosurefanmodule -fanmodule 1 1
The resulting output:
enclosure_id 1
fan_module_id 1
status online
error_sequence_number
FRU_part_number 31P1847
FRU_identity 11S31P1846YM10BG3B101N
fault_LED off