Enclosure indicators provide an overview of the enclosure status. The
enclosure indicators are on the left end cap of the enclosure.
Labels and indicators on the enclosure left end cap provide information about the enclosure and
the enclosure status. The product name, machine type-model, serial number, and type of enclosure
(control or expansion) are shown on the left end cap. When multiple enclosures are in a machine room
or rack, the serial number is used to identify the enclosure being referenced. Figure 1. Left enclosure end cap
1
Enclosure left end cap
2
System name
3
Enclosure Power LED
4
Identify (Locator) LED
5
Enclosure Fault LED
6
Enclosure type label (control or expansion)
7
Product Asset Tag label (displays machine type, serial number, part number,
and 3D bar code)
The LEDs on the left end cap display the status of the enclosure. Table 1 summarizes the meaning of the enclosure LED
activity.
Table 1. Summary of the end cap LEDs
LED name
Call out
Symbol
Color
State
Meaning
Enclosure Operational
3
Green
OFF
The enclosure does not have any power or it is running on battery power.
SLOW BLINK 500 ms ON, 500 ms OFF
All node canisters are powered, but they are in stand-by mode.
Note: Not used
on expansion enclosures.
ON
At least one canister in the enclosure is operational.
Identify (Locator)
4
Blue
OFF
The enclosure is not being identified.
ON
The enclosure has been identified. You can use the
chenclosure command to turn this LED on or off.
Enclosure Fault
5
Amber
OFF
No faults are identified within any hardware component of the
enclosure.
ON
When
ON, this LED indicates one the following:
The enclosure is still in the process of coming up.
An error is logged against the enclosure backplane, a canister, a drive or a PSU within the
enclosure.