Following your enclosure location plan, install the control enclosure.
About this task
The installation procedure applies equally to control enclosures and expansion
enclosures.
Lifting a control enclosure requires at least three people.
Lifting an expansion enclosure requires at least two people.
Each control enclosure must be installed only on the control enclosure rails provided with the
enclosure.
Each expansion enclosure must be installed only on the expansion enclosure rails provided with
the enclosure.
CAUTION:
To lift a control enclosure requires at least three people.
Install a control enclosure only onto the control enclosure
rails supplied with the enclosure.
Load the rack from the bottom up to ensure rack stability. Empty the rack from the top
down.
Procedure
To install an enclosure, complete the following steps.
On either side of the drive assemblies, remove the enclosure end caps by grasping the
handle and pulling the bottom of the end cap free, then clearing the tab on the top of the
enclosure.
(See Figure 1.)Figure 1. Removing enclosure end caps
Align the enclosure with the front of the rack cabinet.
Slide the enclosure into the rack along the rails until the enclosure is fully
inserted. (See Figure 2.)
Note: The rails are not designed to hold an enclosure that is partially inserted. The
enclosure must always be in a fully inserted position. Control
enclosures must be installed only on the supplied control enclosure rails. Do not
install a control enclosure on expansion enclosure
rails.
Figure 2. Inserting the enclosure
Secure the enclosure with screws in the rack mounting
screw holes on each side of the enclosure.
Some enclosures are
secured by one silver captive screw and one black M5 screw on each flange. In this case,
align the enclosure, fasten the two captive screws, and then fasten the two M5 screws.
See Figure 3
Figure 3. Securing the front of the enclosure
Reinstall the left and right end caps.
(See Figure 4.) The left end
cap has indicator windows that align with the status LEDs (light-emitting diodes) on the edge of the
enclosure.
Ensure that the serial number on the left end cap matches the serial number on the left flange
("ear") on the front of the enclosure.
Fit the slot on the top of the end cap over the tab on the flange.
Rotate the end cap down until it snaps into place.
Ensure that the inside surface of the end cap is flush with the flange.
Figure 4. Reinstalling enclosure end caps
What to do next
If you removed components from the enclosure to lift it, reinstall the components into
the slots of the enclosure from which they were removed.