Connecting 2U expansion enclosures to the control enclosure
If you have 2U expansion enclosures in the rack, you must connect them to the control
enclosure.
About this task
This task applies if you are installing one or more expansion enclosures. Each control enclosure in the system can manage two sets of expansion enclosures;
each set can consist of a maximum of 10 expansion enclosures. Therefore, each control enclosure can
manage up to 20 expansion enclosures. A system that contains two control enclosures can have up to
40 expansion enclosures.
Each set of expansion enclosures is connected together sequentially
through the IN and OUT SAS ports, forming a chain with a control enclosure at the end of the
chain.
Note: When you connect SAS cables between enclosures, review and follow the guidelines to ensure
that your configuration is valid. Do not begin connecting the cables until you read SAS cabling guidelines.
Procedure
To install the cables, complete the following steps.
Using the supplied SAS cables, connect the Storwize® V7000 Gen2 control enclosure to the expansion
enclosure at rack position 1, as shown in Figure 1.
Connect SAS port 1 of the left node canister in the control enclosure to SAS port 1 of the left
expansion canister in the first expansion enclosure.
Connect SAS port 1 of the right node canister in the control enclosure to SAS port 1 of the
right expansion canister in the first expansion enclosure.
Figure 1. Connecting the SAS cables to a Storwize V7000 Gen2 control enclosure
Using the supplied SAS cables, connect the Storwize V7000 Gen3 control enclosure to
the expansion enclosure at rack position 1, as shown in Figure 2.
Connect SAS port 1 of the upper node canister in the control enclosure to SAS port 1 of the
left expansion canister in the first expansion enclosure.
Connect SAS port 1 of the lower node canister in the control enclosure to SAS port 1 of the
right expansion canister in the first expansion enclosure.
Figure 2. Connecting the SAS cables to Storwize V7000 Gen3 control enclosure
To add a second expansion enclosure chain to the control enclosure, use the supplied
SAS cables to connect the control enclosure to the expansion enclosure at rack position 2.
Refer to Figure 1 for an example.
Connect SAS port 2 of the left node canister in the control enclosure to SAS port 1
of the left expansion canister in the second expansion enclosure.
Connect SAS port 2 of the right node canister in the control enclosure to SAS port
1 of the right expansion canister in the second expansion enclosure.
To add a second expansion enclosure chain to the Storwize V7000 Gen3 control enclosure, use the supplied
SAS cables to connect the control enclosure to the expansion enclosure at rack position 2. See Figure 2 for an example.
Connect SAS port 3 of the upper node canister in the control enclosure to SAS port 1 of the
left expansion canister in the second expansion enclosure.
Connect SAS port 3 of the lower node canister in the control enclosure to SAS port 1 of the
right expansion canister in the second expansion enclosure.
If more expansion enclosures are installed, connect each one to the previous expansion
enclosure in a chain. Use two Mini SAS HD to Mini SAS HD cables, as shown in Figure 1.
Note: A control enclosure can support up to 20 expansion enclosures (10 above the control enclosure
and 10 below the control enclosure).
If more control enclosures are installed, repeat this cabling procedure on each control
enclosure and its expansion enclosures.