1093 Temperature warning threshold exceeded
Explanation
The system internal temperature sensor has reported that the temperature warning threshold has been exceeded.
User response
- Ensure that the internal airflow of the node has not been obstructed.
- Check node status. If all nodes show a status of
online
, mark the error that you have just repairedfixed
. If any nodes do not show a status ofonline
, go to the start MAP. If you return to this step, contact your support center to resolve the problem. - Go to repair verification MAP.
For the 2145-DH8 only:
- Check for external air flow blockages.
- Remove the top of the machine case and check for missing baffles, damaged heatsinks, or internal blockages.
- If the problem persists after taking these measures, replace the CPU assembly FRU if 2145-DH8.
Possible Cause-FRUs or other:
2145-DH8
- CPU assembly (30%)
Other:
Airflow blockage (70%)